Need Help? Contact Us service@plas.com
Get App

ASA/PA SCHULABLEND® M/MW NC100 A SCHULMAN USA

629

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Melt volume flow rate250°C/5.0kgISO11336.00cm3/10min
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile modulusISO527-2/1A/13100Mpa
Tensile stress屈服ISO527-2/1A/5051.0Mpa
Tensile strain屈服ISO527-2/1A/503.1%
Thermal performanceTest ConditionTest MethodTest ResultUnit
Hot deformation temperature0.45MPa,未退火ISO75-2/Bf96.0°C
Hot deformation temperature1.8MPa,未退火ISO75-2/Af78.0°C
Vicat softening temperature--ISO306/A50184°C
Vicat softening temperature--ISO306/B50110°C
Impact performanceTest ConditionTest MethodTest ResultUnit
Impact strength of simply supported beam without notch-30°CISO179/1eU75kJ/m²
Impact strength of simply supported beam without notch23°CISO179/1eUNoBreak
hardnessTest ConditionTest MethodTest ResultUnit
Ball pressure hardnessH358/10ISO2039-1101Mpa
flammabilityTest ConditionTest MethodTest ResultUnit
Burning rateISO379530mm/min
UL flame retardant rating1.5mmIEC60695-11-10,-20HB
UL flame retardant rating3.0mmIEC60695-11-10,-20HB
Burning wire flammability index1.5mmIEC60695-2-12675°C
Burning wire flammability index3.0mmIEC60695-2-12675°C
Hot filament ignition temperature1.5mmIEC60695-2-13700°C
Hot filament ignition temperature3.0mmIEC60695-2-13700°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.