PA6/66 Ultramid® C3U BASF GERMANY
392
- Properties:High impact resistanceFlame retardant
- Usages:Electrical componentsElectronic insulation
- Certificates:UL
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Shrinkage rate | MD:3.18mm | 0.80 | % | |
Water absorption rate | 饱和 | ASTMD570 | 8.5 | % |
饱和,23°C | ISO62 | 8.5 | % | |
平衡,50%RH | ASTMD570 | 2.9 | % | |
平衡,23°C,50%RH | ISO62 | 2.9 | % | |
Melt volume flow rate | 275°C/5.0kg | ISO1133 | 140 | cm3/10min |
Density/specific gravity | ASTMD792 | 1.16 | g/cm³ | |
ISO1183 | 1.16 | g/cm³ |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile strength | 屈服,23°C | ASTMD638 | 83.0 | Mpa |
Nominal tensile fracture strain | 23°C | ISO527-2 | 6.0 | % |
Tensile stress | 屈服,23°C | ISO527-2 | 75.0 | Mpa |
Tensile strain | 屈服,23°C | ISO527-2 | 4.0 | % |
Tensile modulus | 23°C | ISO527-2 | 3500 | Mpa |
elongation | 断裂,23°C | ASTMD638 | 50 | % |
屈服,23°C | ASTMD638 | 5.0 | % | |
Bending modulus | 23°C | ASTMD790 | 3000 | Mpa |
23°C | ISO178 | 3000 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Hot deformation temperature | 0.45MPa,未退火 | ASTMD648 | 224 | °C |
1.8MPa,未退火 | ASTMD648 | 91.0 | °C | |
1.8MPa,未退火 | ISO75-2/A | 70.0 | °C | |
RTIElec | 0.38mm | UL746 | 110 | °C |
0.75mm | UL746 | 120 | °C | |
1.5mm | UL746 | 120 | °C | |
3.0mm | UL746 | 120 | °C | |
Evolution Calendar intelligent importer | 0.38mm | UL746 | 65.0 | °C |
0.75mm | UL746 | 105 | °C | |
1.5mm | UL746 | 105 | °C | |
3.0mm | UL746 | 105 | °C | |
RTIStr | 0.38mm | UL746 | 65.0 | °C |
0.75mm | UL746 | 115 | °C | |
1.5mm | UL746 | 120 | °C | |
3.0mm | UL746 | 120 | °C | |
Peak melting temperature | ASTMD3418 | 243 | °C | |
Melting temperature (DSC) | ISO3146 | 243 | °C | |
Linear coefficient of thermal expansion | MD | ASTME831 | 4E-05 | cm/cm/°C |
MD | 8E-05 | cm/cm/°C | ||
TD | 9E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Dielectric strength | IEC60243-1 | 32 | KV/mm | |
Leakage Trace Index | IEC60112 | 600 | V | |
VolumeResistivity | 1.50mm | ASTMD257 | 1E+13 | ohms·cm |
Dissipation factor | 1MHz | IEC60250 | 0.020 | |
Dielectric constant | 1MHz | IEC60250 | 3.60 | |
Volume resistivity | IEC60093 | 1E+13 | ohms·cm |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO179 | 80 | kJ/m² |
Charpy Notched Impact Strength | -30°C | ISO179 | 4.0 | kJ/m² |
23°C | ISO179 | 9.0 | kJ/m² | |
Impact strength of cantilever beam gap | -40°C | ASTMD256 | 32 | J/m |
23°C | ASTMD256 | 43 | J/m | |
23°C | ISO180 | 4.5 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Ball pressure hardness | ISO2039-1 | 100 | Mpa |
flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
UL flame retardant rating | 0.38mm | UL94 | V-0 | |
0.75mm | UL94 | V-0 | ||
1.5mm | UL94 | V-0 | ||
3.0mm | UL94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.