PA6/66 Ultramid® C3U BASF GERMANY
222
- Unit Price:
- $9602 USD/MT
- Packaging Specification:
- 25 KG/PKG
- Supply Quantity:
- 10MT
- Delivery Terms:
- FOB
- Port of Loading:
- China Main Port
- Accepted Payment Methods:
- T/T
- Shipping:
- Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 2787 3515View
serv********View
For more detailed information including pricing, customization, and shipping, please contact supplier.
Material Description
Technical Data Sheet
Material Description
- Material Properties:High impact resistance Flame retardant
- Application Areas:Electrical components Electronic insulation
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Density/specific gravity | ASTMD792 | 1.16 | g/cm³ | |
ISO1183 | 1.16 | g/cm³ | ||
Melt volume flow rate | 275°C/5.0kg | ISO1133 | 140 | cm3/10min |
Shrinkage rate | MD:3.18mm | 0.80 | % | |
Water absorption rate | Saturation | ASTMD570 | 8.5 | % |
Saturation,23°C | ISO62 | 8.5 | % | |
Equilibrium,50%RH | ASTMD570 | 2.9 | % | |
Equilibrium,23°C,50%RH | ISO62 | 2.9 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile modulus | 23°C | ISO527-2 | 3500 | Mpa |
Tensile strength | Yield,23°C | ASTMD638 | 83.0 | Mpa |
Tensile stress | Yield,23°C | ISO527-2 | 75.0 | Mpa |
elongation | Yield,23°C | ASTMD638 | 5.0 | % |
Tensile strain | Yield,23°C | ISO527-2 | 4.0 | % |
elongation | Break,23°C | ASTMD638 | 50 | % |
Nominal tensile fracture strain | 23°C | ISO527-2 | 6.0 | % |
Bending modulus | 23°C | ASTMD790 | 3000 | Mpa |
23°C | ISO178 | 3000 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Linear coefficient of thermal expansion | MD | 8E-05 | cm/cm/°C | |
TD | 9E-05 | cm/cm/°C | ||
RTIElec | 0.38mm | UL746 | 110 | °C |
0.75mm | UL746 | 120 | °C | |
1.5mm | UL746 | 120 | °C | |
3.0mm | UL746 | 120 | °C | |
Evolution Calendar intelligent importer | 0.38mm | UL746 | 65.0 | °C |
0.75mm | UL746 | 105 | °C | |
1.5mm | UL746 | 105 | °C | |
3.0mm | UL746 | 105 | °C | |
Hot deformation temperature | 0.45MPa,Unannealed | ASTMD648 | 224 | °C |
1.8MPa,Unannealed | ASTMD648 | 91.0 | °C | |
1.8MPa,Unannealed | ISO75-2/A | 70.0 | °C | |
Peak melting temperature | ASTMD3418 | 243 | °C | |
Melting temperature (DSC) | ISO3146 | 243 | °C | |
Linear coefficient of thermal expansion | MD | ASTME831 | 4E-05 | cm/cm/°C |
RTIStr | 0.38mm | UL746 | 65.0 | °C |
0.75mm | UL746 | 115 | °C | |
1.5mm | UL746 | 120 | °C | |
3.0mm | UL746 | 120 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
VolumeResistivity | 1.50mm | ASTMD257 | 1E+13 | ohms·cm |
Volume resistivity | IEC60093 | 1E+13 | ohms·cm | |
Dielectric strength | IEC60243-1 | 32 | KV/mm | |
Dielectric constant | 1MHz | IEC60250 | 3.60 | |
Dissipation factor | 1MHz | IEC60250 | 0.020 | |
Leakage Trace Index | IEC60112 | 600 | V |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Impact strength of cantilever beam gap | -40°C | ASTMD256 | 32 | J/m |
23°C | ASTMD256 | 43 | J/m | |
23°C | ISO180 | 4.5 | kJ/m² | |
Charpy Notched Impact Strength | -30°C | ISO179 | 4.0 | kJ/m² |
23°C | ISO179 | 9.0 | kJ/m² | |
Impact strength of simply supported beam without notch | 23°C | ISO179 | 80 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Ball pressure hardness | ISO2039-1 | 100 | Mpa |
flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
UL flame retardant rating | 0.38mm | UL94 | V-0 | |
0.75mm | UL94 | V-0 | ||
1.5mm | UL94 | V-0 | ||
3.0mm | UL94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.