Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | TD | ISO294-4 | 1.6 | % |
Shrinkage rate | MD | ISO294-4 | 1.6 | % |
Water absorption rate | 23°C,24hr | ISO62 | 0.30 | % |
Water absorption rate | 饱和,23°C,2.00mm | ISO62 | 0.60 | % |
Water absorption rate | 平衡,23°C,2.00mm,50%RH | ISO62 | 0.20 | % |
Melt mass flow rate | 240°C/2.16kg | ISO1133 | 13 | g/10min |
Melt volume flow rate | 240°C/2.16kg | ISO1133 | 12.0 | cm3/10min |
Density/specific gravity | | ISO1183 | 1.26 | g/cm³ |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Nominal tensile fracture strain | | ISO527-2 | 530 | % |
Tensile creep modulus | 1000hr | ISO899-1 | 310 | Mpa |
Tensile creep modulus | 1hr | ISO899-1 | 360 | Mpa |
abrasion resistance | | ISO4649 | 100 | mm³ |
Tensile stress | 屈服 | ISO527-2 | 26.0 | Mpa |
Tensile stress | 断裂 | ISO527-2 | 50.0 | Mpa |
Tensile stress | 5.0%应变 | ISO527-2 | 14.0 | Mpa |
Tensile stress | 10%应变 | ISO527-2 | 23.0 | Mpa |
Tensile stress | 50%应变 | ISO527-2 | 24.0 | Mpa |
Tensile strain | 屈服 | ISO527-2 | 26 | % |
Tensile strain | 断裂 | ISO527-2 | >300 | % |
Tensile modulus | | ISO527-2 | 550 | Mpa |
Bending modulus | | ISO178 | 550 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | 0.45MPa,未退火 | ISO75-2/B | 100 | °C |
Hot deformation temperature | 1.8MPa,未退火 | ISO75-2/A | 50.0 | °C |
Brittle temperature | | ISO974 | -97.0 | °C |
Vicat softening temperature | -- | ISO306/A50 | 205 | °C |
Vicat softening temperature | -- | ISO306/B50 | 140 | °C |
Linear coefficient of thermal expansion | EffectiveThermalDiffusivity | ISO11359-2 | 8E-08 | m²/s |
Linear coefficient of thermal expansion | MD | ISO11359-2 | 1.8E-04 | cm/cm/°C |
Linear coefficient of thermal expansion | TD | ISO11359-2 | 1.7E-04 | cm/cm/°C |
Glass transition temperature 3 | | ISO11357-2 | 25.0 | °C |
Melting temperature 3 | | ISO11357-3 | 218 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric strength | | IEC60243-1 | 20 | KV/mm |
Relative permittivity | 100Hz | IEC60250 | 4.00 | |
Relative permittivity | 1MHz | IEC60250 | 3.50 | |
Leakage Trace Index | | IEC60112 | 600 | V |
Surface resistivity | | IEC60093 | >1.0E+15 | ohms |
Volume resistivity | | IEC60093 | 2E+12 | ohms·cm |
Dissipation factor | 100Hz | IEC60250 | 0.016 | |
Dissipation factor | 1MHz | IEC60250 | 0.030 | |
elastomer | Test Condition | Test Method | Test Result | Unit |
---|
tear strength | 横向流量 | ISO34-1 | 170 | kN/m |
tear strength | 流量 | ISO34-1 | 180 | kN/m |
Filling analysis | Test Condition | Test Method | Test Result | Unit |
---|
SpecificHeatCapacity of Melt | | | 2150 | J/kg/°C |
ThermalConductivityofMelt | | | 0.15 | W/m/K |
Melt density | | | 1.11 | g/cm³ |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Notched Impact Strength | -40°C | ISO179/1eA | 7.0 | kJ/m² |
Charpy Notched Impact Strength | -30°C | ISO179/1eA | 8.0 | kJ/m² |
Charpy Notched Impact Strength | 23°C | ISO179/1eA | 36 | kJ/m² |
Impact strength of cantilever beam gap | -40°C | ISO180/1A | 7.0 | kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO180/1A | 38 | kJ/m² |
Tensile impact strength | 23°C | ISO8256/1 | 300 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Shore hardness | 邵氏D | ISO868 | 68 | |
Shore hardness | 邵氏D,15秒 | ISO868 | 64 | |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
Burning rate 4 | 1.00mm | ISO3795 | DNI | |
UL flame retardant rating | 1.5mm | UL94,IEC60695-11-10,-20 | HB | |
Extreme Oxygen Index | | ISO4589-2 | 23 | % |
Supplementary Information | Test Condition | Test Method | Test Result | Unit |
---|
EmissionofOrganicCompounds | | VDA277 | 300 | µgC/g |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.