Need Help? Contact Us service@plas.com
Get App

PBT VALOX™  ENH4550 SABIC INNOVATIVE US

305
  • Properties:
    High rigidity
    Glass fiber reinforced
  • Usages:
    Electrical applications
    Automotive Applications
  • Certificates:
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Shrinkage rateMD:--2内部方法0.10to0.50%
Shrinkage rateMD:3.20mm内部方法0.10to0.50%
Shrinkage rateTD:--2内部方法0.60to1.2%
Shrinkage rateTD:3.20mm内部方法0.50to1.1%
Water absorption rate饱和,23°CISO620.23%
Water absorption rate平衡,23°C,50%RHISO620.060%
Melt mass flow rate250°C/5.0kgASTMD123827g/10min
Melt volume flow rate250°C/5.0kgISO113320.0cm3/10min
MeltViscosity250°C,1500sec^-1ISO11443210Pa·s
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile stress屈服ISO527-2/5112Mpa
Tensile stress断裂ISO527-2/5112Mpa
Tensile strain屈服ISO527-2/52.0%
Tensile strain断裂ISO527-2/52.0%
Tensile modulusISO527-2/110400Mpa
Elongation rate 4断裂ASTMD6382.0%
Elongation rate 4屈服ASTMD6382.0%
Bending modulus 550.0mmSpanASTMD7909100Mpa
FlexuralStrength5Yield,50.0mmSpanASTMD790161Mpa
Tensile strength 4屈服ASTMD638105Mpa
Bending strength 6,7ISO178170Mpa
Tensile modulus 3ASTMD6389900Mpa
Tensile strength 4BreakASTMD638105Mpa
Bending modulus 6ISO1789400Mpa
Fracture bending strain 8ISO1782.0%
Thermal performanceTest ConditionTest MethodTest ResultUnit
Hot deformation temperature 110.45MPa,Unannealed,64.0mmSpanISO75-2/Bf219°C
Hot deformation temperature 111.8MPa,Unannealed,64.0mmSpanISO75-2/Af201°C
BallPressure Test125°CIEC60695-10-2Pass
Hot deformation temperature0.45MPa,未退火,3.20mmASTMD648216°C
Hot deformation temperature1.8MPa,未退火,3.20mmASTMD648204°C
Vicat softening temperature--ASTMD152512215°C
Vicat softening temperature--ASTMD152513202°C
Vicat softening temperature--ISO306/A50219°C
Vicat softening temperature--ISO306/B50206°C
Vicat softening temperature--ISO306/B120206°C
RTIElecUL746130°C
Evolution Calendar intelligent importerUL746140°C
RTIStrUL746140°C
Linear coefficient of thermal expansionTD:-40to40°CASTME8317.1E-05cm/cm/°C
Linear coefficient of thermal expansionTD:-40to150°CASTME8317.7E-05cm/cm/°C
Linear coefficient of thermal expansionTD:-40to40°CISO11359-27.6E-05cm/cm/°C
Linear coefficient of thermal expansionTD:23到80°CISO11359-29.1E-05cm/cm/°C
Linear coefficient of thermal expansionMD:-40to40°CASTME8312.7E-05cm/cm/°C
Linear coefficient of thermal expansionMD:-40to150°CASTME8312.2E-05cm/cm/°C
Linear coefficient of thermal expansionMD:-40to40°CISO11359-23E-05cm/cm/°C
Linear coefficient of thermal expansionMD:23到80°CISO11359-22.2E-05cm/cm/°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dielectric strength3.20mm,在油中ASTMD14921KV/mm
Dielectric strength3.20mm,inAirASTMD14921KV/mm
Compared to the anti leakage trace indexCTIUL746PLC2
Leakage Trace IndexIEC60112300V
Volume resistivityASTMD2571.0E+15to1.0E+16ohms·cm
Volume resistivityIEC600931.0E+15to1.0E+16ohms·cm
Arc resistance 14ASTMD495PLC6
Hot wire ignitionHWIUL746PLC0
High arc combustion indexHAIUL746PLC0
High voltage arc tracing rateHVTRUL746PLC0
Impact performanceTest ConditionTest MethodTest ResultUnit
Suspended wall beam gap impact strength 10-30°CISO180/1A7.0kJ/m²
Suspended wall beam gap impact strength 1023°CISO180/1A7.0kJ/m²
Unscented Izod Impact Strength 10-30°CISO180/1U29kJ/m²
Unscented Izod Impact Strength 1023°CISO180/1U33kJ/m²
Impact strength of simply supported beam without notch-30°CISO179/2U33kJ/m²
Impact strength of simply supported beam without notch23°CISO179/2U36kJ/m²
Dart impact equipped with measuring instruments23°C,TotalEnergyASTMD37636.50J
flammabilityTest ConditionTest MethodTest ResultUnit
Hot filament ignition temperature0.8mmIEC60695-2-13775°C
Hot filament ignition temperature3.0mm15IEC60695-2-13775°C
UL flame retardant rating0.75mmUL94V-0
UL flame retardant rating3.0mmUL945VA
Burning wire flammability index0.75mmIEC60695-2-12960°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.