Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D792/ISO 1183 | 1.22 | |
Modeling Shrinkage | | ASTM D955 | 1.2 | % |
Moisture Absorption 23℃/24H | | ASTM D570/ISO 62 | 7.1 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Notched Izod Impact Strength | 23℃,DAM | ASTM D-256 | 48 | J/m |
Notched Izod Impact Strength | 23℃,50%RH | ASTM D-256 | 53 | J/m |
Tensile Elongation?(Break) | | ASTM D638/ISO 527 | 2 | % |
Tensile Elongation?(Break) | 23℃,50%RH | ASTM D-638 | 8 | % |
Tensile Elongation?(Break) | 23℃,DAM | ASTM D-638 | 2 | % |
Tensile Strength | 23℃,50%RH | ASTM D-638 | 82.7 | Mpa |
Tensile Strength | 23℃,DAM | ASTM D-638 | 103.4 | Mpa |
Tensile Strength | | ASTM D638/ISO 527 | 103.4 | kg/cm²(MPa)[Lb/in²] |
Flexural Modulus | | ASTM D790/ISO 178 | 4826 | kg·cm/cm(J/M)ft·lb/in |
Flexural Strength | | ASTM D790/ISO 178 | 165 | kg·cm/cm(J/M)ft·lb/in |
Flexural strength | 23℃,DAM | ASTM D-790 | 165 | Mpa |
Flexural Modulus | 23℃,DAM | ASTM D-790 | 4826 | Mpa |
Flexural Modulus | 23℃,50%RH | ASTM D-790 | 2758 | Mpa |
Taber wear | 50%RH | | 12 | cycles |
Rockwell hardness R | DAM | ASTM D-785 | R122 | |
Rockwell hardness R | 50%RH | ASTM D-785 | R113 | |
Rockwell Hardness(M-Scale) | 50%RH | ASTM D-785 | M84 | |
Rockwell Hardness(M-Scale) | DAM | ASTM D-785 | M95 | |
Shearing Strength | 23℃,DAM | ASTM D-732 | 76 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Burning Rate | | UL94 | HB | |
Melting Temperature | | | 255 | ℃(℉) |
Melting Temperature | 50%RH | ASTM D-789 | 255 | °C |
Melting Temperature | DAM | ASTM D-789 | 255 | °C |
Linear expansion coefficient | | ASTM D696/ISO 11359 | 2.7×10-5 | mm/mm.℃ |
Coefficient of Linear Thermal Expansion | | ASTM D-696 | 2.7×10 | m/m/℃ |
Thermal distortion temperature | 1.8MPa | ASTM D-648 | 243 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Constant | | ASTM D150/IEC 60250 | 130 | |
Dielectric Constant | | ASTM D150/IEC 60250 | 150 | |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | Saturation(23℃) | ASTM D-570 | 7.1 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.