Material Description
Technical Data Sheet
Material Description
- Material Properties:Flame retardant High mobility
- Application Areas:electrical equipment Automotive Applications Lighting installation
- Color:--
- Grade:Medical grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Shrinkage rate | MD:2.00mm3 | ISO294-4 | 0.60 | % |
Water absorption rate | Saturation,23°C | ISO62 | 0.30 | % |
Equilibrium,23°C,50%RH | ISO62 | 0.12 | % | |
Apparent density | ISO60 | 0.66 | g/cm³ | |
Melt mass flow rate | 300°C/1.2kg | ISO1133 | 16 | g/10min |
Melt volume flow rate | 300°C/1.2kg | ISO1133 | 15.0 | cm3/10min |
Shrinkage rate | TD | ISO2577 | 0.60to0.80 | % |
MD | ISO2577 | 0.60to0.80 | % | |
TD:2.00mm3 | ISO294-4 | 0.65 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile modulus | 23°C | ISO527-2/1 | 2400 | Mpa |
Tensile stress | Yield,23°C | ISO527-2/50 | 67.0 | Mpa |
Break,23°C | ISO527-2/50 | 75.0 | Mpa | |
Tensile strain | Yield,23°C | ISO527-2/50 | 6.1 | % |
Break,23°C | ISO527-2/50 | 130 | % | |
Nominal tensile fracture strain | 23°C | ISO527-2/50 | >50 | % |
Bending modulus 4 | 23°C | ISO178 | 2400 | Mpa |
Bending stress 4 | 3.5%Strain,23°C | ISO178 | 74.0 | Mpa |
23°C | ISO178 | 100 | Mpa | |
Bending strain 5 | 23°C | ISO178 | 7.0 | % |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Hot deformation temperature | 0.45MPa,Unannealed | ISO75-2/B | 134 | °C |
1.8MPa,Unannealed | ISO75-2/A | 122 | °C | |
Glass transition temperature 8 | ISO11357-2 | 142 | °C | |
Vicat softening temperature | -- | ISO306/B50 | 141 | °C |
-- | ISO306/B120 | 142 | °C | |
BallPressure Test | 132°C | IEC60695-10-2 | Pass | |
Linear coefficient of thermal expansion | MD:23to55°C | ISO11359-2 | 6.5E-05 | cm/cm/°C |
TD:23to55°C | ISO11359-2 | 6.5E-05 | cm/cm/°C | |
Thermal conductivity coefficient 9 | 23°C | ISO8302 | 0.20 | W/m/K |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Surface resistivity | IEC60093 | 1E+16 | ohms | |
Volume resistivity | 23°C | IEC60093 | 1E+16 | ohms·cm |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Impact strength of simply supported beam gap 6 | -30°C,Complete Break | ISO7391 | 14 | kJ/m² |
23°C,Partial Break | ISO7391 | 70 | kJ/m² | |
Impact strength of simply supported beam without notch | -60°C | ISO179/1eU | NoBreak | |
-30°C | ISO179/1eU | NoBreak | ||
23°C | ISO179/1eU | NoBreak | ||
Suspended wall beam gap impact strength 7 | -30°C,Complete Break | ISO7391 | 12 | kJ/m² |
23°C,Partial Break | ISO7391 | 65 | kJ/m² | |
Multi axis Instrumented Impact Energy | -30°C | ISO6603-2 | 70.0 | J |
23°C | ISO6603-2 | 60.0 | J | |
Multi axis Instrumented Peak Impact Force | -30°C | ISO6603-2 | 6200 | N |
23°C | ISO6603-2 | 5300 | N |
hardness | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Ball pressure hardness | ISO2039-1 | 118 | Mpa |
flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Extreme Oxygen Index 10 | ISO4589-2 | 27 | % | |
FlashIgnitionTemperature | ASTMD1929 | 480 | °C | |
SelfIgnition | ASTMD1929 | 550 | °C |
Supplementary Information | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
ISO Shortcut | ISO7391-PC,M,(,,)-18-9 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.