PEI ULTEM™  HU1000-1H1000 SABIC INNOVATIVE US

134
  • Unit Price:
    $24503 USD/MT
  • Packaging Specification:
    25 KG/PKG
  • Supply Quantity:
    10MT
  • Delivery Terms:
    FOB
  • Port of Loading:
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 2787 3515View
serv********View

For more detailed information including pricing, customization, and shipping, please contact supplier.

Material Description
Technical Data Sheet

Material Description

  • Material Properties:Middle flow Biocompatibility Steam sterilization
  • Application Areas:Medical and nursing suppl Medical devices
  • Color:--
  • Grade:--

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest ResultUnit
Melt flow rate337°C/6.6 kgASTM D12389.0g/10 min
Molten Volume Flow Rate (MVR)220°C/5.0 kgISO 113313.0cm3/10min
Shrinkage rate - flow3.20 mm内部方法0.50 到 0.70%
Water absorption rate24 hrASTM D5700.25%
Water absorption rateSaturation, 23°CISO 621.3%
Water absorption rateEquilibrium, 23°CASTM D5701.3%
Water absorption rateEquilibrium, 23°C, 50% RHISO 620.70%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile modulus-- 2ASTM D6383580Mpa
Tensile modulus--ISO 527-2/13200Mpa
Tensile strengthYield 3ASTM D638110Mpa
Tensile strengthYieldISO 527-2/5105Mpa
Tensile strengthBreak 3ASTM D63890.0Mpa
Tensile strengthBreakISO 527-2/585.0Mpa
elongationYield 3ASTM D6387.0%
elongationYieldISO 527-2/56.0%
elongationBreak 3ASTM D63860%
elongationBreakISO 527-2/560%
Bending modulus50.0 mm Span 4ASTM D7903430Mpa
Bending modulus-- 5ISO 1783300Mpa
Bending stress-- 5, 6ISO 178160Mpa
Bending stressYield, 50.0 mm Span 4ASTM D790173Mpa
Thermal performanceTest ConditionTest MethodTest ResultUnit
Thermal deformation temperature under load1.8 MPa, Unannealed, 6.40 mmASTM D648201°C
Thermal deformation temperature under load1.8 MPa, Unannealed, 4.00 mm, 64.0 mm Span 8ISO 75-2/Af215°C
Vicat softening temperature--ASTM D15259218°C
Vicat softening temperature--ISO 306/B50215°C
Vicat softening temperature--ISO 306/B120211°C
Linear coefficient of thermal expansionFlow : -20 to 150°CASTM E8315.6E-5cm/cm/°C
Linear coefficient of thermal expansionFlow : -40 to 40°CISO 11359-25.0E-5cm/cm/°C
Linear coefficient of thermal expansionAcross Flow : -20 to 150°CASTM E8315.4E-5cm/cm/°C
Linear coefficient of thermal expansionAcross Flow : -40°CISO 11359-25.0E-5cm/cm/°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Volume resistivityASTM D2571.0E+17ohms·cm
Dielectric strength1.60 mm, in AirASTM D14933KV/mm
Dielectric strength1.60 mm, in OilASTM D14928KV/mm
Dielectric constant1 kHzASTM D1503.15
Dissipation factor1 kHzASTM D1501.3E-3
Dissipation factor2.45 GHzASTM D1502.5E-3
Arc resistance 10ASTM D495PLC 5
Compared to the Leakage Tracking Index (CTI)UL 746PLC 4
High arc combustion index (HAI) 11UL 746PLC 3
High Voltage Arc Traceability Rate (HVTR)UL 746PLC 2
Hot wire ignition (HWI)UL 746PLC 1
injectionTest ConditionTest MethodTest ResultUnit
drying temperature150°C
drying time4.0 到 6.0hr
Suggested maximum moisture content0.020%
Suggested injection volume40 到 60%
Temperature at the rear of the barrel330 到 400°C
Temperature in the middle of the barrel340 到 400°C
Temperature at the front of the material cylinder345 到 400°C
Spray nozzle temperature345 到 400°C
Processing (melt) temperature350 到 400°C
Mold temperature135 到 165°C
Back pressure0.300 到 0.700Mpa
Screw speed40 到 70rpm
Exhaust hole depth0.025 到 0.076mm
Impact performanceTest ConditionTest MethodTest ResultUnit
Non notched cantilever beam impact23°CASTM D48121300J/m
Dart impact equipped with measuring instruments23°C, Total EnergyASTM D37630.00J
flammabilityTest ConditionTest MethodTest ResultUnit
Extreme Oxygen IndexASTM D286347%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.