Technical Data Sheet
Compare
Physical properties | Test Condition | Test Method | Test Result | Unit |
---|
density | | ASTM D792/ISO 1183 | 1.08 | |
Water absorption rate 23 ℃/24h | | ASTM D570/ISO 62 | 0.1 | % |
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | 2.00mm | 内部方法 | 0.50to0.70 | % |
Water absorption rate | 23°C,24hr | ISO62 | 0.10 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile stress | Yield,23°C | ISO527-2 | 37.0 | Mpa |
Nominal tensile fracture strain | 23°C | ISO527-2 | 30 | % |
Bending modulus | 23°C | ISO178 | 2370 | Mpa |
Bending stress | 23°C | ISO178 | 66.0 | Mpa |
elongation at break | | ASTM D638/ISO 527 | 40 | % |
tensile strength | | ASTM D638/ISO 527 | 36 | kg/cm²(MPa)[Lb/in²] |
Rockwell hardness | | ASTM D785 | R110 | |
Bending modulus | | ASTM D790/ISO 178 | 2250 | kg/cm²(MPa)[Lb/in²] |
bending strength | | ASTM D790/ISO 178 | 59 | kg/cm²(MPa)[Lb/in²] |
Tensile stress | | ASTM D-638 | 39 | Mpa |
Elongation rate | | ASTM D-638 | 40 | % |
Bending modulus | | ASTM D-790 | 2350 | Mpa |
bending strength | | ASTM D-790 | 59 | Mpa |
Flame retardant grade | | UL 94 | V-0 | |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Combustibility (rate) | | UL94 | V-0 | |
Hot deformation temperature | | ASTM D648/ISO 75 | 85 | ℃(℉) |
Hot deformation temperature | 1.8MPa,Unannealed | ASTMD648 | 85.0 | °C |
Hot deformation temperature | 1.8MPa,Unannealed | ISO75-2/A | 78.0 | °C |
Linear coefficient of thermal expansion | MD:-30to65°C | ISO11359-2 | 8E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface resistivity | | IEC60093 | 1E+16 | ohms |
Volume resistivity | 23°C | IEC60093 | 1E+16 | ohms·cm |
Dielectric strength 5 | 2.00mm | IEC60243-1 | 29 | KV/mm |
Dielectric constant | 100Hz | IEC60250 | 2.90 | |
Dielectric constant | 1MHz | IEC60250 | 2.90 | |
Dissipation factor | 100Hz | IEC60250 | 3E-03 | |
Dissipation factor | 1MHz | IEC60250 | 4E-03 | |
Processing performance | Test Condition | Test Method | Test Result | Unit |
---|
Mold temperature | | | 40-70 | °C |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of simply supported beam gap 3 | 23°C | ISO179 | 16 | kJ/m² |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 1.5mm | UL94 | V-0 | |
UL flame retardant rating | 3.0mm | UL94 | 5VA | |
Basic performance | Test Condition | Test Method | Test Result | Unit |
---|
density | | ASTM D-792 | 1.08 | g/cm |
Shrinkage rate | | ASTM D-955 | 0.50-0.70 | % |
Water absorption rate | | ASTM D-570 | 0.10 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.