Need Help? Contact Us service@plas.com
Get App

ASA Luran®S  KR2863C BASF GERMANY

385
  • Properties:
    High temperature resistan
    UV resistance
    high strength
  • Usages:
    Electrical tools
    Automotive sector
  • Certificates:
    UL

Technical Data Sheet

Physical PropertiesTest ConditionTest MethodTest ResultUnit
Modeling ShrinkageISO294-40.50到0.90%
Moisture Absorption饱和,23°CISO620.60%
Moisture Absorption平衡,23°C,50%RHISO620.16%
Melt Volume flow Rate220°C/10.0kgISO11337.00cm3/10min
Melt Volume flow Rate260°C/5.0kgISO113318.0cm3/10min
Density / Specific GravityISO11831.16g/cm³
Mechanical PropertiesTest ConditionTest MethodTest ResultUnit
Flexural StressISO17893.0Mpa
Tensile Stress屈服,23°CISO527-262.0Mpa
Tensile Strain屈服,23°CISO527-24.9%
Tensile ModulusISO527-22500Mpa
Thermal PropertiesTest ConditionTest MethodTest ResultUnit
Linear thermal expansion coefficientMDISO11359-27.0E-5到9.0E-5cm/cm/°C
Vicat Softening Temperature--ISO306/A50140°C
Vicat Softening Temperature--ISO306/B50130°C
Thermal ConductivityDIN526120.17W/m/K
Heat Deflection Temperature0.45MPa,退火ISO75-2/B130°C
Heat Deflection Temperature1.8MPa,退火ISO75-2/A109°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Surface ResistivityIEC600931E+14ohms
Dielectric Constant100HzIEC602503.10
Volume ResistivityIEC600931E+15ohms·cm
Dissipation Factor?100HzIEC602506E-03
Dissipation Factor?1MHzIEC602500.010
FilmTest ConditionTest MethodTest ResultUnit
Elongation - MD断裂ISO527-3>50%
Impact PropertiesTest ConditionTest MethodTest ResultUnit
Charpy Notched Impact Strength-30°CISO17917kJ/m²
Charpy Notched Impact Strength23°CISO17960kJ/m²
Notched Izod Impact Strength-30°CISO180/A10kJ/m²
Notched Izod Impact Strength23°CISO180/A60kJ/m²
hardnessTest ConditionTest MethodTest ResultUnit
Ball Indentation HardnessISO2039-1110Mpa
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.