Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | MD:3.20mm | 内部方法 | 0.50to0.70 | % |
Melt Mass-Flow Rate | 337°C/6.6kg | ASTMD1238 | 9.5 | g/10min |
K (wear) Factor | --2 | 内部方法 | 72.0 | |
K (wear) Factor | --3 | 内部方法 | 27.0 | |
| | 内部方法 | 1.9 | MPa·m/s |
Density / Specific Gravity | | ASTMD792 | 1.33 | g/cm³ |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Modulus | | ASTMD638 | 3360 | Mpa |
Flexural Modulus | 100mmSpan | ASTMD790 | 3410 | Mpa |
Tensile Strength | Yield | ASTMD638 | 103 | Mpa |
Tensile Elongation | 断裂 | ASTMD638 | 40 | % |
Flexural Strength | Yield,100mmSpan | ASTMD790 | 152 | Mpa |
Taber Abrasion Resistance | 1000Cycles,1000g,CS-17转轮 | ASTMD1044 | 2.00 | mg |
Coefficient of Friction | 与钢-动态 | ASTMD1894 | 0.25 | |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
RTIElec | | UL746 | 170 | °C |
Evolution Calendar intelligent importer | | UL746 | 170 | °C |
RTIStr | | UL746 | 170 | °C |
Deflection Temperature Under Load? | 1.8MPa,未退火,6.40mm | ASTMD648 | 200 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Arc Resistance | | ASTMD495 | PLC6 | |
Comparative Tracking Index | CTI | UL746 | PLC4 | |
Hot-wire Ignition | HWI | UL746 | PLC1 | |
High Amp Arc Ignition | HAI | UL746 | PLC0 | |
High Voltage Arc Tracking Rate | HVTR | UL746 | PLC2 | |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Reverse Notch Izod Impact | 3.20mm | ASTMD256 | 1300 | J/m |
Notched Izod Impact Strength | 23°C | ASTMD256 | 120 | J/m |
Notched Izod Impact Strength | 23°C | ASTMD4812 | 530 | J/m |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M级 | ASTMD785 | 110 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.38mm | UL94 | V-0 | |
UL flame retardant rating | 1.5mm | UL94 | 5VA | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.