PC Makrolon® 9417 700394 COVESTRO SHANGHAI
262
- Properties:high viscosityHigh temperature resistanFiller: Glass fiber reinf10% filler by weight10% filler by weight
- Usages:Electronic and electricalAutomotive Applications
- Certificates:UL
Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Modeling Shrinkage | MD:2.00mm3 | ISO294-4 | 0.60 | % |
TD | ISO2577 | 0.40to0.60 | % | |
MD | ISO2577 | 0.40to0.60 | % | |
TD:2.00mm3 | ISO294-4 | 0.45 | % | |
Moisture Absorption | 饱和,23°C | ISO62 | 0.26 | % |
平衡,23°C,50%RH | ISO62 | 0.10 | % | |
Melt Mass-Flow Rate | 300°C/1.2kg | ISO1133 | 7.0 | g/10min |
Melt Volume flow Rate | 300°C/1.2kg | ISO1133 | 6.00 | cm3/10min |
Density / Specific Gravity | 23°C | ISO1183 | 1.27 | g/cm³ |
Apparent Density | ISO60 | 0.64 | g/cm³ |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Flexural Strain | 23°C | ISO178 | 5.8 | % |
Flexural Stress | 3.5%Strain,23°C | ISO178 | 95.0 | Mpa |
23°C | ISO178 | 105 | Mpa | |
Flexural Modulus | 23°C | ISO178 | 3600 | Mpa |
Tensile Creep Modulus | 1hr | ISO899-1 | 3600 | Mpa |
Tensile Stress | 屈服,23°C | ISO527-2/5 | 64.0 | Mpa |
断裂,23°C | ISO527-2/5 | 45.0 | Mpa | |
Tensile Strain | 屈服,23°C | ISO527-2/5 | 4.6 | % |
断裂,23°C | ISO527-2/5 | 15 | % | |
Tensile Creep Modulus | 1000hr | ISO899-1 | 2900 | Mpa |
Tensile Modulus | 23°C | ISO527-2/1 | 3800 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Deflection Temperature Under Load? | 0.45MPa,未退火 | ISO75-2/B | 141 | °C |
1.8MPa,未退火 | ISO75-2/A | 135 | °C | |
Ball PressureTest | 136°C | IEC60695-10-2 | Pass | |
RTIElec | 1.5mm | UL746 | 125 | °C |
Evolution Calendar intelligent importer | 1.5mm | UL746 | 115 | °C |
RTIStr | 1.5mm | UL746 | 125 | °C |
Vicat Softening Temperature | -- | ISO306/B50 | 143 | °C |
-- | ISO306/B120 | 144 | °C | |
Linear thermal expansion coefficient | MD:23到55°C | ISO11359-2 | 4E-05 | cm/cm/°C |
TD:23to55°C | ISO11359-2 | 6.5E-05 | cm/cm/°C | |
Thermal Conductivity | 23°C | ISO8302 | 0.22 | W/m/K |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Dielectric Strength | 23°C,1.00mm | IEC60243-1 | 36 | KV/mm |
Dissipation Factor? | 23°C,100Hz | IEC60250 | 1E-03 | |
23°C,1MHz | IEC60250 | 9E-03 | ||
Relative Permittivity | 23°C,100Hz | IEC60250 | 3.20 | |
23°C,1MHz | IEC60250 | 3.20 | ||
Comparative Tracking Index | 解决方案A | IEC60112 | 175 | V |
解决方案B | IEC60112 | 125 | V | |
Surface Resistivity | IEC60093 | 1E+16 | ohms | |
Volume Resistivity | 23°C | IEC60093 | 1E+16 | ohms·cm |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Charpy Unnotched Impact Strength | -60°C,CompleteBreak | ISO179/1eU | 100 | kJ/m² |
-30°C,完全断裂 | ISO179/1eU | 120 | kJ/m² | |
23°C,完全断裂 | ISO179/1eU | 150 | kJ/m² | |
Multi-Axial Instrumented Impact Energy | 23°C | ISO6603-2 | 25.0 | J |
-30°C | ISO6603-2 | 15.0 | J | |
23°C,CompleteBreak | ISO7391 | 10 | kJ/m² | |
Notched Izod Impact Strength | 23°C,CompleteBreak | ISO7391 | 10 | kJ/m² |
Multi-Axial Instrumented Impact Peak Force | -30°C | ISO6603-2 | 3700 | N |
23°C | ISO6603-2 | 4000 | N |
hardness | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Ball Indentation Hardness | ISO2039-1 | 128 | Mpa |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Oxygen Index | ISO4589-2 | 35 | % | |
ApplicationofFlamefromSmallBurner MethodKandF | 2.00mm | DIN53438-1,-3 | K1,F1 | |
UL flame retardant rating | 1.5mm | UL94 | V-0 | |
3.0mm,NC,BK,GY | UL94 | 5VA | ||
6.0mm | UL94 | 5VA | ||
Glow Wire Flammability Index | 0.75mm | IEC60695-2-12 | 960 | °C |
1.5mm | IEC60695-2-12 | 960 | °C | |
3.0mm | IEC60695-2-12 | 960 | °C | |
Glow Wire Ignition Temperature | 1.0mm | IEC60695-2-13 | 825 | °C |
1.5mm | IEC60695-2-13 | 900 | °C | |
3.0mm | IEC60695-2-13 | 900 | °C | |
FMVSS Flammability | >1.00mm | ISO3795 | passed | |
FlashIgnition | ASTMD1929 | 470 | °C | |
SelfIgnition | ASTMD1929 | 550 | °C |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
ElectrolyticalCorrosion | 23°C | IEC60426 | A1 | |
ISO Shortname | ISO7391-PC,MFLR,(,,)-09-9,GF10 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.