Need Help? Contact Us service@plas.com
Get App

PC Makrolon®  9417 700394 COVESTRO SHANGHAI

262
  • Properties:
    high viscosity
    High temperature resistan
    Filler: Glass fiber reinf
    10% filler by weight
    10% filler by weight
  • Usages:
    Electronic and electrical
    Automotive Applications
  • Certificates:
    UL

Technical Data Sheet

Physical PropertiesTest ConditionTest MethodTest ResultUnit
Modeling ShrinkageMD:2.00mm3ISO294-40.60%
Modeling ShrinkageTDISO25770.40to0.60%
Modeling ShrinkageMDISO25770.40to0.60%
Modeling ShrinkageTD:2.00mm3ISO294-40.45%
Moisture Absorption饱和,23°CISO620.26%
Moisture Absorption平衡,23°C,50%RHISO620.10%
Melt Mass-Flow Rate300°C/1.2kgISO11337.0g/10min
Melt Volume flow Rate300°C/1.2kgISO11336.00cm3/10min
Density / Specific Gravity23°CISO11831.27g/cm³
Apparent DensityISO600.64g/cm³
Mechanical PropertiesTest ConditionTest MethodTest ResultUnit
Flexural Strain23°CISO1785.8%
Flexural Stress3.5%Strain,23°CISO17895.0Mpa
Flexural Stress23°CISO178105Mpa
Flexural Modulus23°CISO1783600Mpa
Tensile Creep Modulus1hrISO899-13600Mpa
Tensile Stress屈服,23°CISO527-2/564.0Mpa
Tensile Stress断裂,23°CISO527-2/545.0Mpa
Tensile Strain屈服,23°CISO527-2/54.6%
Tensile Strain断裂,23°CISO527-2/515%
Tensile Creep Modulus1000hrISO899-12900Mpa
Tensile Modulus23°CISO527-2/13800Mpa
Thermal PropertiesTest ConditionTest MethodTest ResultUnit
Deflection Temperature Under Load?0.45MPa,未退火ISO75-2/B141°C
Deflection Temperature Under Load?1.8MPa,未退火ISO75-2/A135°C
Ball PressureTest136°CIEC60695-10-2Pass
RTIElec1.5mmUL746125°C
Evolution Calendar intelligent importer1.5mmUL746115°C
RTIStr1.5mmUL746125°C
Vicat Softening Temperature--ISO306/B50143°C
Vicat Softening Temperature--ISO306/B120144°C
Linear thermal expansion coefficientMD:23到55°CISO11359-24E-05cm/cm/°C
Linear thermal expansion coefficientTD:23to55°CISO11359-26.5E-05cm/cm/°C
Thermal Conductivity23°CISO83020.22W/m/K
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dielectric Strength23°C,1.00mmIEC60243-136KV/mm
Dissipation Factor?23°C,100HzIEC602501E-03
Dissipation Factor?23°C,1MHzIEC602509E-03
Relative Permittivity23°C,100HzIEC602503.20
Relative Permittivity23°C,1MHzIEC602503.20
Comparative Tracking Index解决方案AIEC60112175V
Comparative Tracking Index解决方案BIEC60112125V
Surface ResistivityIEC600931E+16ohms
Volume Resistivity23°CIEC600931E+16ohms·cm
Impact PropertiesTest ConditionTest MethodTest ResultUnit
Charpy Unnotched Impact Strength-60°C,CompleteBreakISO179/1eU100kJ/m²
Charpy Unnotched Impact Strength-30°C,完全断裂ISO179/1eU120kJ/m²
Charpy Unnotched Impact Strength23°C,完全断裂ISO179/1eU150kJ/m²
Multi-Axial Instrumented Impact Energy23°CISO6603-225.0J
Multi-Axial Instrumented Impact Energy-30°CISO6603-215.0J
23°C,CompleteBreakISO739110kJ/m²
Notched Izod Impact Strength23°C,CompleteBreakISO739110kJ/m²
Multi-Axial Instrumented Impact Peak Force-30°CISO6603-23700N
Multi-Axial Instrumented Impact Peak Force23°CISO6603-24000N
hardnessTest ConditionTest MethodTest ResultUnit
Ball Indentation HardnessISO2039-1128Mpa
FlammabilityTest ConditionTest MethodTest ResultUnit
Oxygen IndexISO4589-235%
ApplicationofFlamefromSmallBurner MethodKandF2.00mmDIN53438-1,-3K1,F1
UL flame retardant rating1.5mmUL94V-0
UL flame retardant rating3.0mm,NC,BK,GYUL945VA
UL flame retardant rating6.0mmUL945VA
Glow Wire Flammability Index0.75mmIEC60695-2-12960°C
Glow Wire Flammability Index1.5mmIEC60695-2-12960°C
Glow Wire Flammability Index3.0mmIEC60695-2-12960°C
Glow Wire Ignition Temperature1.0mmIEC60695-2-13825°C
Glow Wire Ignition Temperature1.5mmIEC60695-2-13900°C
Glow Wire Ignition Temperature3.0mmIEC60695-2-13900°C
FMVSS Flammability>1.00mmISO3795passed
FlashIgnitionASTMD1929470°C
SelfIgnitionASTMD1929550°C
Supplementary informationTest ConditionTest MethodTest ResultUnit
ElectrolyticalCorrosion23°CIEC60426A1
ISO ShortnameISO7391-PC,MFLR,(,,)-09-9,GF10
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.