Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Melt Volume flow Rate | 380°C/5.0kg | ISO1133 | 12.0 | cm3/10min |
Density / Specific Gravity | 23°C | ISO1183 | 1.30 | g/cm³ |
Modeling Shrinkage | TD:180°C,2.00mm | ISO294-4 | 1.1 | % |
Modeling Shrinkage | MD:180°C,2.00mm | ISO294-4 | 0.90 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Modulus | | ISO527-2 | 3500 | Mpa |
Tensile Stress | 屈服 | ISO527-2 | 96.0 | Mpa |
Tensile Strain | 屈服 | ISO527-2 | 5.0 | % |
Tensile Strain | 断裂 | ISO527-2 | 30 | % |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Vicat Softening Temperature | -- | ISO306/A | 335 | °C |
Vicat Softening Temperature | -- | ISO306/B | 305 | °C |
Linear thermal expansion coefficient | MD:23到55°C | ISO11359-2 | 6E-05 | cm/cm/°C |
Melting Temperature | | ISO11357-3 | 340 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Relative Permittivity | 50Hz | IEC60250 | 2.80 | |
Relative Permittivity | 1MHz | IEC60250 | 2.80 | |
Comparative Tracking Index | SolutionA5 | IEC60112 | 175 | V |
Comparative Tracking Index | 解决方案A | IEC60112 | 200 | V |
Surface Resistivity | | IEC60093 | 1E+14 | ohms |
Volume Resistivity | | IEC60093 | 1E+15 | ohms·cm |
Dielectric Strength | | IEC60243-1 | 16 | KV/mm |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Notched Impact Strength | -30°C,完全断裂 | ISO179/1eA | 6.0 | kJ/m² |
Charpy Notched Impact Strength | 23°C,完全断裂 | ISO179/1eA | 7.0 | kJ/m² |
Charpy Unnotched Impact Strength | -30°C | ISO179/1eU | NoBreak | |
Charpy Unnotched Impact Strength | 23°C | ISO179/1eU | NoBreak | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 3.2mm | UL94 | V-0 | |
Glow Wire Flammability Index | 2.0mm | IEC60695-2-12 | 960 | °C |
Glow Wire Ignition Temperature | 2.0mm | IEC60695-2-13 | 825 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.