Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | | ASTM D-955 | 3-5 | in/inE-3 |
Solid Content | | ASTM D-792 | 1.42 | |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Strength (Yield) | | ASTM D-790 | 28700 | psi |
IZOD Notch Impact Strength | | ASTM D-256 | 9.0 | ft-lb/in |
Rockwell Hardness | | ASTM D-785 | 114 | psi |
Flexural Modulus | | ASTM D-790 | 809000 | psi |
Unnotched Izod Impact Strength | | ASTM D-4812 | 1.6 | ft-lb/in |
Tensile Elongation (Break) | | ASTM D-638 | 3.0 | % |
Tensile Strength (Yield) | | ASTM D-638 | 20100 | psi |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Temperature Index | 电性能 | UL746B | 170 | °C |
Temperature Index | 机械冲击性能 | UL746B | 170 | °C |
Temperature Index | 非机械性能 | UL746B | 170 | °C |
Coefficient of Linear Thermal Expansion | flow | ASTM E-831 | 1×10 | E-5/in/in℉ |
Coefficient of Linear Thermal Expansion | xflow | ASTM E-831 | - | E-5/in/in℉ |
Deflection Temperature Under Load? | 66Psi | ASTM D-648 | 410 | ℉ |
Deflection Temperature Under Load? | 264Psi | ASTM D-648 | 408 | ℉ |
Vicat Softening Temperature | | ASTM D-1525 | 428 | ℉ |
Flammability | | UL 94 | V-0 | CLASS |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric Strength | 62mils | ASTM D-149 | 670 | v/mil |
Dielectric Constant | 1KHz | ASTM D-150 | 3.50 | |
Volume Resistivity | | ASTM D-257 | 7×10 | Ω.cm |
Loss factor | 1KHz | ASTM D-150 | 0.0015 | |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Melt index | | ASTM D-1238 | 5.6 | g/10min |
Moisture Absorption | 24小时,73℉ | ASTM D-570 | 0.190 | % |
Moisture Absorption | 平衡,73℉ | ASTM D-570 | 1.10 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.