TPE Hytrel® 6356 DUPONT USA
219
- Properties:Thermal stability
- Usages:Electrical toolsWire and cableIndustrial applicationspipelinesheetAutomotive sector
- Certificates:UL
Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Modeling Shrinkage | TD | ISO294-4 | 1.5 | % |
MD | ISO294-4 | 1.5 | % | |
Moisture Absorption | 23°C,24hr | ISO62 | 0.50 | % |
饱和,23°C,2.00mm | ISO62 | 0.60 | % | |
平衡,23°C,2.00mm,50%RH | ISO62 | 0.20 | % | |
Melt Mass-Flow Rate | 230°C/2.16kg | ISO1133 | 9.0 | g/10min |
MediumDensity | 1.06 | g/cm³ | ||
SpecificHeatCapacityofMelt | 2150 | J/kg/°C | ||
ThermalConductivityofMelt | 0.15 | W/m/K | ||
Melt Volume flow Rate | 230°C/2.16kg | ISO1133 | 8.50 | cm3/10min |
Density / Specific Gravity | ISO1183 | 1.22 | g/cm³ |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Nominal Tensile Strain at Break | ISO527-2 | 500 | % | |
Abrasion Resistance | ISO4649 | 110 | mm³ | |
Tensile Creep Modulus | 1000hr | ISO899-1 | 182 | Mpa |
1hr | ISO899-1 | 248 | Mpa | |
Tensile Stress | 屈服 | ISO527-2 | 20.0 | Mpa |
断裂 | ISO527-2 | 43.0 | Mpa | |
5.0%应变 | ISO527-2 | 12.0 | Mpa | |
10%应变 | ISO527-2 | 15.0 | Mpa | |
50%应变 | ISO527-2 | 18.8 | Mpa | |
100%应变 | ISO527-2 | 19.0 | Mpa | |
Tensile Strain | 屈服 | ISO527-2 | 31 | % |
断裂 | ISO527-2 | >300 | % | |
Tensile Modulus | ISO527-2 | 280 | Mpa | |
Flexural Modulus | ISO178 | 290 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Deflection Temperature Under Load? | 0.45MPa,未退火 | ISO75-2/B | 80.0 | °C |
1.8MPa,未退火 | ISO75-2/A | 45.0 | °C | |
Brittleness Temperature | ISO974 | -96.0 | °C | |
Vicat Softening Temperature | -- | ISO306/A50 | 195 | °C |
-- | ISO306/B50 | 100 | °C | |
Melting Temperature | ISO11357-3 | 210 | °C | |
Linear thermal expansion coefficient | MD:-- | ISO11359-2 | 1.9E-04 | cm/cm/°C |
MD:-40to23°C | ISO11359-2 | 1.6E-04 | cm/cm/°C | |
TD:23to55°C | ASTME831 | 1.7E-04 | cm/cm/°C | |
TD:-- | ISO11359-2 | 1.8E-04 | cm/cm/°C | |
TD:-40to23°C | ISO11359-2 | 1.5E-04 | cm/cm/°C | |
TD:EffectiveThermalDiffusivity | ISO11359-2 | 5.44E-08 | m²/s | |
Glass Transition Temperature | ISO11357-2 | 0.00 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Relative Permittivity | 100Hz | IEC60250 | 4.60 | |
1MHz | IEC60250 | 4.10 | ||
Dielectric Strength | IEC60243-1 | 20 | KV/mm | |
Surface Resistivity | IEC60093 | >1.0E+15 | ohms | |
Volume Resistivity | IEC60093 | 8E+13 | ohms·cm | |
Dissipation Factor? | 100Hz | IEC60250 | 0.012 | |
1MHz | IEC60250 | 0.036 |
Elastomers Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tearing Strength | 横向流量 | ISO34-1 | 150 | kN/m |
流量 | ISO34-1 | 160 | kN/m |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Charpy Notched Impact Strength | -40°C | ISO179/1eA | 15 | kJ/m² |
-30°C | ISO179/1eA | 25 | kJ/m² | |
23°C,局部断裂 | ISO179/1eA | 120 | kJ/m² | |
Notched Izod Impact Strength | -40°C | ISO180/1A | 19 | kJ/m² |
23°C | ISO180/1A | 81 | kJ/m² | |
Tensile Impact Strength | 23°C | ISO8256/1 | 300 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Shore Hardness | 邵氏D | ISO868 | 63 | |
邵氏D,15秒 | ISO868 | 57 |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
UL flame retardant rating | 1.5mm | UL94 | HB | |
3.0mm | UL94 | HB | ||
1.5mm | IEC60695-11-10,-20 | HB | ||
3.0mm | IEC60695-11-10,-20 | HB | ||
Oxygen Index | ISO4589-2 | 21 | % | |
FMVSS Flammability | FMVSS302 | SE | ||
Fogging-G-value | condensate | ISO6452 | 1E-04 | g |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
EmissionofOrganicCompounds | VDA277 | 2.50 | µgC/g | |
Odor | VDA270 | 2.50 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.