Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D-792 | 1.11 | |
Modeling Shrinkage | | ASTM D-955 | 5-7 | in/in E-3 |
Modeling Shrinkage | | ASTM D-955 | 5-7 | in/in E-3 |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Instrumented Dart Impact (-30℃) | | ASTM D-3763 | 8.6 | ft-lbs |
Reverse Notched Impact Strength | | ASTM D-256 | 12.0 | ft-lb/in |
Flexural Strength (Yield) | | ASTM D-790 | 14400 | psi |
Notched Izod Impact Strength | | ASTM D-256 | 1.8 | ft-lb/in |
Tensile Elongation (Yield) | | ASTM D-638 | 8.0 | % |
Reverse Notched Izod Impact Strength (23℃) | | ASTM D 256 | 16.6 | ft-lb/in |
Instrumented Dart Impact (23℃) | | ASTM D-3763 | 29.0 | ft-lbs |
Tensile Strength (Break) | | ASTM D 638 | 7200 | psi |
Notched Izod Impact Strength (23℃) | | ASTM D-256 | 3.5 | ft-lb/in |
Tensile Elongation (Break) | | ASTM D-638 | 17.0 | % |
Tensile Strength | | ASTM D-638 | 9700 | psi |
Tensile Modulus | | ASTM D-790 | 361500 | psi |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Heat Deflection Temperature | | ASTM D-648 | 211 | deg F |
UL | | | E121562 | |
Heat Deflection Temperature | | UL 746B | 95 | deg C |
Heat Deflection Temperature | | UL 746B | 80 | deg C |
Heat Deflection Temperature | | ASTM D-648 | 229 | deg F |
V-0 Rating | 测试厚度 | UL 94 | 0.060 | inch |
Vicat Softening Temperature | | ASTM D-1525 | 264 | deg F |
5VA Rating | 测试厚度 | UL 94 | 0.120 | inch |
Hot-wire Ignition | | UL 746B | 95 | deg C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface Resistivity | | ASTM D-257 | >1 E14 | ohm/sq |
Volume Resistivity | | ASTM D-257 | 2E+16 | ohm-cm |
Dissipation Factor (50Hz) | | ASTM D-150 | 0.0100 | |
Dielectric Constant (50Hz) | | ASTM D-150 | 2.69 | |
Dissipation Factor (1 MHz) | | ASTM D-150 | 0.0070 | |
Dielectric Constant (1 MHz) | | ASTM D-150 | 2.55 | |
Dielectric Strength | | ASTM D-149 | 414 | v/mil |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.