Need Help? Contact Us service@plas.com
Get App

ABS POLYLAC®  PA-766 TAIWAN CHIMEI

352
  • Properties:
    Flame retardant
    heat-resisting
    High impact resistance
  • Usages:
    Electrical field
    Electronic field
  • Certificates:
    UL

Technical Data Sheet

Physical PropertiesTest ConditionTest MethodTest ResultUnit
DensityASTM D792/ISO 11831.20
Melt Mass-Flow RateASTM D1238/ISO 113325g/10min
Physical PropertiesTest ConditionTest MethodTest ResultUnit
Melt index220℃×10kgASTM D-123825g/10min
Melt index200℃ 5kgASTM D-12382.3g/10min
Mechanical PropertiesTest ConditionTest MethodTest ResultUnit
Tensile StrengthASTM D638/ISO 527370kg/cm²(MPa)[Lb/in²]
Tensile ElongationASTM D-63830%
Rockwell HardnessASTM D-78595R
Rockwell HardnessASTM D78595
Flexural ModulusASTM D790/ISO 1782.0×104kg/cm²(MPa)[Lb/in²]
Flexural StrengthASTM D790/ISO 1788360kg/cm²(MPa)[Lb/in²]
Flexural StrengthASTM D-790590kg/cm
Flexural StrengthASTM D-7908360lb/in
Bending elasticityASTM D-7902.0×10kg/cm
Bending elasticityASTM D-7902.8×10lb/in
Tensile strengthASTM D-6385250lb/in
Tensile strengthASTM D-638370kg/cm
Izod notch impact strengthASTM D256/ISO 1793.9kg·cm/cm(J/M)ft·lb/in
Izod notch impact strengthASTM D256/ISO 17923kg·cm/cm(J/M)ft·lb/in
Izod Impact Strength1/4〃ASTM D-2563.9ft.lb/in
Izod Impact Strength1/8"ASTM D-25623kg.cm/cm
Izod Impact Strength1/4〃ASTM D-25621kg.cm/cm
Izod Impact Strength1/8"ASTM D-2564.3ft.lb/in
Thermal PropertiesTest ConditionTest MethodTest ResultUnit
FlammabilityFile No. E56070 UL&C-UL1/16"V-O
Deflection Temperature Under Load?ASTM D648/ISO 7589(192)℃(℉)
Deflection Temperature Under Load?ASTM D-64889(192)°C
Deflection Temperature Under Load?ASTM D-64881(178)
Vicat Softening TemperatureASTM D-152598°C
Vicat Softening TemperatureASTM D-1525214
Vicat Softening TemperatureASTM D1525/ISO R30698℃(℉)
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.