Need Help? Contact Us service@plas.com
Get App

PA46 Stanyl®  TE250F8(NC) DSM HOLAND

152
  • Properties:
    Thermal stability
    Flame retardant
    Glass fiber reinforced
  • Usages:
    Automotive Applications
    Lighting fixtures
  • Certificates:
    UL

Technical Data Sheet

Physical PropertiesTest ConditionTest MethodTest ResultUnit
Modeling Shrinkage横向流量ISO 294-40.90%
Modeling Shrinkage流量ISO 294-40.30%
Moisture Absorption平衡, 23°C, 50% RHISO 621.3%
DensityISO 11831.77g/cm³
Mechanical PropertiesTest ConditionTest MethodTest ResultUnit
Tensile Stress断裂ISO 527-2180Mpa
Tensile Stress断裂, 120°CISO 527-2100Mpa
Tensile Stress断裂, 160°CISO 527-285.0Mpa
Tensile Strain断裂ISO 527-21.9%
Tensile Strain断裂, 120°CISO 527-23.0%
Tensile Strain断裂, 160°CISO 527-23.0%
Tensile Modulus--ISO 527-215000Mpa
Tensile Modulus120°CISO 527-29500Mpa
Tensile Modulus160°CISO 527-26500Mpa
Flexural Modulus--ISO 17813000Mpa
Flexural Modulus120°CISO 1788500Mpa
Flexural Modulus160°CISO 1785500Mpa
Thermal PropertiesTest ConditionTest MethodTest ResultUnit
Deflection Temperature Under Load?0.45 MPa, 未退火ISO 75-2/B290°C
Deflection Temperature Under Load?1.8 MPa, 未退火ISO 75-2/A290°C
IEC 60216163°C
Linear thermal expansion coefficient流动ISO 11359-22.5E-5cm/cm/°C
Linear thermal expansion coefficient横向ISO 11359-25.0E-5cm/cm/°C
RTI Elec0.35 mmUL 746130°C
Melting TemperatureISO 11357-3295°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dielectric StrengthIEC 60243-130KV/mm
Relative Permittivity100 HzIEC 602504.30
Relative Permittivity1 MHzIEC 602504.00
Relative Permittivity1.00 GHzIEC 602503.60
Comparative Tracking IndexIEC 60112325V
Volume ResistivityIEC 600931.0E+15ohms·cm
Impact PropertiesTest ConditionTest MethodTest ResultUnit
Charpy Unnotched Impact Strength-30°CISO 179/1eU40kJ/m²
Charpy Unnotched Impact Strength23°CISO 179/1eU50kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA13kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA13kJ/m²
Notched Izod Impact Strength-40°CISO 180/1A14kJ/m²
Notched Izod Impact Strength23°CISO 180/1A14kJ/m²
FlammabilityTest ConditionTest MethodTest ResultUnit
Flammability level0.35 mmIEC 60695-11-10, -20V-0
Flammability level1.5 mmIEC 60695-11-10, -20V-0
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.