Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D792/ISO 1183 | 1.56 | |
Moisture Absorption 23℃/24H | | ASTM D570/ISO 62 | 0.5 | % |
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | 3.2mm,flow | ASTM D-792 | DAM|0.4 | % |
Modeling Shrinkage | 3.2mm,flow | ASTM D-792 | 50%RH|- | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
IZOD Notch Impact Strength | | ASTM D-256 | DAM|100 | J/m |
IZOD Notch Impact Strength | | ASTM D-256 | 50%RH|105 | J/m |
Tensile Elongation?(Break) | | ASTM D638/ISO 527 | 2.5 | % |
Tensile Strength | | ASTM D638/ISO 527 | 169 | kg/cm²(MPa)[Lb/in²] |
Tensile Strength | | ASTN D-638 | DAM|169 | Mpa |
Tensile Strength | | ASTN D-638 | 50%RH|134 | Mpa |
Tensile Elongation | 断裂 | ASTM D-638 | DAM|2.5 | % |
Tensile Elongation | 断裂 | ASTM D-638 | 50%RH|4 | % |
Flexural Modulus | | ASTM D790/ISO 178 | 8960 | kg·cm/cm(J/M)ft·lb/in |
Flexural Modulus | | ASTM D-790 | DAM|8960 | Mpa |
Flexural Modulus | | ASTM D-790 | 50%RH|6900 | Mpa |
Flexural Strength | | ASTM D790/ISO 178 | 240 | kg·cm/cm(J/M)ft·lb/in |
Flexural Strength | | ASTM D-790 | DAM|240 | Mpa |
Flexural Strength | | ASTM D-790 | 50%RH|- | Mpa |
Izod notch impact strength | | ASTM D256/ISO 179 | 100 | kg·cm/cm(J/M)ft·lb/in |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | | ASTM D648/ISO 75 | 235 | ℃(℉) |
Deflection Temperature Under Load? | | ASTM D648/ISO 75 | 257 | ℃(℉) |
Deflection Temperature Under Load? | 0.45MPa | ASTM D-648 | DAM|257 | °C |
Deflection Temperature Under Load? | 0.45MPa | ASTM D-648 | 50%RH|- | °C |
Deflection Temperature Under Load? | 1.80MPa | ASTM D-648 | DAM|235 | °C |
Deflection Temperature Under Load? | 1.80MPa | ASTM D-648 | 50%RH|- | °C |
Melting Temperature | | | 262 | ℃(℉) |
Melting Temperature | | ASTM D-3418 | DAM|262 | °C |
Melting Temperature | | ASTM D-3418 | 50%RH|- | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface Resistivity | | ASTM D257/IEC 60093 | 10 | Ω |
Surface Resistivity | | ASTM D-257 | DAM|1014 | |
Surface Resistivity | | ASTM D-257 | 50%RH|1011 | |
Dielectric Constant | 106Hz | ASTM D-150 | DAM|3.5 | |
Dielectric Constant | 106Hz | ASTM D-150 | 50%RH|3.8 | |
Dielectric Constant | | ASTM D150/IEC 60250 | 17.2 | |
Dielectric Constant | | ASTM D150/IEC 60250 | 3.6 | |
Dielectric Constant | 103Hz | ASTM D-150 | DAM|3.6 | |
Dielectric Constant | 103Hz | ASTM D-150 | 50%RH|5.1 | |
Volume Resistivity | | ASTM D-257 | DAM|1014 | Ω.m |
Volume Resistivity | | ASTM D-257 | 50%RH|1011 | Ω.m |
Volume Resistivity | | ASTM D257/IEC 60093 | 10 | Ω.cm |
Dielectric Strength | 3.2mm | ASTM D-149 | DAM|17.2 | KV/mm |
Dielectric Strength | 3.2mm | ASTM D-149 | 50%RH|15.6 | KV/mm |
Loss factor | 103Hz | ASTM D-150 | DAM|0.009 | |
Loss factor | 103Hz | ASTM D-150 | 50%RH|0.113 | |
Loss factor | 106Hz | ASTM D-150 | DAM|0.014 | |
Loss factor | 106Hz | ASTM D-150 | 50%RH|0.041 | |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | 24hr | ASTM D-570 | DAM|0.5 | % |
Moisture Absorption | 24hr | ASTM D-570 | 50%RH|- | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.