PA6/66 Ultramid® C3U BK BASF GERMANY
239
- Properties:High impact resistanceFlame retardant
- Usages:Electrical componentsElectronic insulation
- Certificates:UL
Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Modeling Shrinkage | MD:3.18mm | 0.80 | % | |
Moisture Absorption | 饱和 | ASTMD570 | 8.5 | % |
饱和,23°C | ISO62 | 8.5 | % | |
平衡,50%RH | ASTMD570 | 2.9 | % | |
平衡,23°C,50%RH | ISO62 | 2.9 | % | |
Melt Volume flow Rate | 275°C/5.0kg | ISO1133 | 140 | cm3/10min |
Density / Specific Gravity | ASTMD792 | 1.16 | g/cm³ | |
ISO1183 | 1.16 | g/cm³ |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Tensile Strength | 屈服,23°C | ASTMD638 | 83.0 | Mpa |
Nominal Tensile Strain at Break | 23°C | ISO527-2 | 6.0 | % |
Tensile Stress | 屈服,23°C | ISO527-2 | 75.0 | Mpa |
Tensile Strain | 屈服,23°C | ISO527-2 | 4.0 | % |
Tensile Modulus | 23°C | ISO527-2 | 3500 | Mpa |
Tensile Elongation | 屈服,23°C | ASTMD638 | 5.0 | % |
断裂,23°C | ASTMD638 | 50 | % | |
Flexural Modulus | 23°C | ASTMD790 | 3000 | Mpa |
23°C | ISO178 | 3000 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Deflection Temperature Under Load? | 0.45MPa,未退火 | ASTMD648 | 224 | °C |
1.8MPa,未退火 | ASTMD648 | 91.0 | °C | |
1.8MPa,未退火 | ISO75-2/A | 70.0 | °C | |
RTIElec | 0.38mm | UL746 | 110 | °C |
0.75mm | UL746 | 120 | °C | |
1.5mm | UL746 | 120 | °C | |
3.0mm | UL746 | 120 | °C | |
Evolution Calendar intelligent importer | 0.38mm | UL746 | 65.0 | °C |
0.75mm | UL746 | 105 | °C | |
1.5mm | UL746 | 105 | °C | |
3.0mm | UL746 | 105 | °C | |
RTIStr | 0.38mm | UL746 | 65.0 | °C |
0.75mm | UL746 | 115 | °C | |
1.5mm | UL746 | 120 | °C | |
3.0mm | UL746 | 120 | °C | |
Peak Melting Temperature | ASTMD3418 | 243 | °C | |
Melting temperature (DSC) | ISO3146 | 243 | °C | |
Linear thermal expansion coefficient | MD | ASTME831 | 4E-05 | cm/cm/°C |
MD | 8E-05 | cm/cm/°C | ||
TD | 9E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Dielectric Strength | IEC60243-1 | 32 | KV/mm | |
Comparative Tracking Index | IEC60112 | 600 | V | |
Volume Resistivity | 1.50mm | ASTMD257 | 1E+13 | ohms·cm |
Dissipation Factor? | 1MHz | IEC60250 | 0.020 | |
Dielectric Constant | 1MHz | IEC60250 | 3.60 | |
Volume Resistivity | IEC60093 | 1E+13 | ohms·cm |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Charpy Unnotched Impact Strength | 23°C | ISO179 | 80 | kJ/m² |
Charpy Notched Impact Strength | -30°C | ISO179 | 4.0 | kJ/m² |
23°C | ISO179 | 9.0 | kJ/m² | |
Notched Izod Impact Strength | -40°C | ASTMD256 | 32 | J/m |
23°C | ASTMD256 | 43 | J/m | |
23°C | ISO180 | 4.5 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
Ball Indentation Hardness | ISO2039-1 | 100 | Mpa |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|---|---|---|---|
UL flame retardant rating | 0.38mm | UL94 | V-0 | |
0.75mm | UL94 | V-0 | ||
1.5mm | UL94 | V-0 | ||
3.0mm | UL94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.