Need Help? Contact Us service@plas.com
Get App

HIPS POLYREX®  PH-888H ZHENJIANG CHIMEI

628
  • Properties:
    heat-resisting
    High rigidity
    High temperature resistan
  • Usages:
    Refrigerator
    Computer accessories
    Electrical field
    Electrical appliances
    TV
    Electronic field
    Video tape
  • Certificates:
    SGS
    UL
    MSDS

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Density/specific gravity--3ASTMD7921.05g/cm³
Density/specific gravity23°CISO11831.05g/cm³
Melt mass flow rate200°C/5.0kgASTMD12383.8g/10min
Melt volume flow rate200°C/5.0kgISO11333.80cm3/10min
Shrinkage rateISO294-40.40到0.70%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile stress屈服ISO527-2/5030.0Mpa
Tensile stress断裂4ASTMD63829.4Mpa
Tensile stress断裂ISO527-2/5030.0Mpa
elongation断裂4ASTMD63845%
elongation断裂ISO527-2/5050%
Bending modulus--5ASTMD7901930Mpa
Bending modulus--6ISO1781500Mpa
bending strength --5ASTMD79044.1Mpa
bending strength --6ISO17839.0Mpa
Thermal performanceTest ConditionTest MethodTest ResultUnit
Hot deformation temperature1.8MPa,未退火ASTMD64882.0°C
Hot deformation temperature1.8MPa,未退火ISO75-2/A79.0°C
Hot deformation temperature1.8MPa,退火ASTMD64897.0°C
Hot deformation temperature1.8MPa,退火ISO75-2/A96.0°C
Vicat softening temperature--ASTMD15257,ISO306/A507102°C
Vicat softening temperature--ISO306/B5092.0°C
Linear coefficient of thermal expansionMDISO11359-24.0E-5到6.0E-5cm/cm/°C
Impact performanceTest ConditionTest MethodTest ResultUnit
Charpy Notched Impact Strength -30°CISO1795.2kJ/m²
Charpy Notched Impact Strength 23°CISO1799.0kJ/m²
Impact strength of cantilever beam gap23°C,3.20mmASTMD25697J/m
Impact strength of cantilever beam gap23°C,6.40mmASTMD25683J/m
Impact strength of cantilever beam gap-30°CISO180/1A4.5kJ/m²
Impact strength of cantilever beam gap23°CISO180/1A8.0kJ/m²
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell hardnessL计秤ASTMD78563
flammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant rating1.5mmUL94HB
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.