PPA AMODEL®  AF-4133 VO BK324 SOLVAY USA

323
  • Properties:
    Flame retardant
    High temperature resistan
    Filler: Glass fiber reinf
    33% filler by weight
  • Usages:
    Electrical/Electronic App
    Electrical components
    Electronic and electrical
    Engine parts
    Automotive components
    Vehicle electronics
  • Certificates:
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Shrinkage rateMDASTMD9550.40%
Shrinkage rateTDASTMD9550.80%
Water absorption rate24hrASTMD5700.23%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile stress断裂,23°CISO527-2210Mpa
Tensile strain断裂,23°CISO527-22.5%
Tensile modulus23°CISO527-212000Mpa
Bending modulus23°CISO17810700Mpa
Bending stress23°CISO178295Mpa
Bending strainISO1783.1%
Thermal performanceTest ConditionTest MethodTest ResultUnit
Glass transition temperatureDSC95.0°C
Linear coefficient of thermal expansionMD:0to100°CASTME8312E-05cm/cm/°C
Linear coefficient of thermal expansionMD:100到200°CASTME8311.5E-05cm/cm/°C
Linear coefficient of thermal expansionTD:0to100°CASTME8317.6E-05cm/cm/°C
Linear coefficient of thermal expansionTD:100到200°CASTME8311.2E-04cm/cm/°C
Melting temperatureISO11357-3327°C
Hot deformation temperature1.8MPa,未退火ISO75-2/A>300°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dielectric constant60HzASTMD1504.10
Dielectric constant1MHzASTMD1503.75
Volume resistivityASTMD2575.6E+15ohms·cm
Dielectric strength3.20mmASTMD14919KV/mm
Dissipation factor1MHzASTMD1500.015
Dissipation factor60HzASTMD1506E-03
High voltage arc tracing rateHVTRUL74614.0mm/min
Compared to the anti leakage trace indexCTIUL746600V
Impact performanceTest ConditionTest MethodTest ResultUnit
Unscented Izod impact strength23°CISO180/1U68kJ/m²
Impact strength of simply supported beam without notch23°CISO179/1eU79kJ/m²
flammabilityTest ConditionTest MethodTest ResultUnit
FlameRating23.2mmUL94HB
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.