Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | | | 0.3 | MD% |
Shrinkage rate | | | 1.2 | TD% |
Water absorption rate | | D570 | 2.8 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile modulus | | ISO 527-1 | 7300(4000) | Mpa |
elongation | 断裂 | | 2.9(5.4) | % |
Bending modulus | | D178 | 6600(4200) | Mpa |
bending strength | | D178 | 234(148) | Mpa |
Fracture stress | | | 150(90) | Mpa |
Pendulum impact strength | | ISO 179 | 43(85) | KJ/m |
Notch pendulum impact strength | | ISO 179 | 8(16) | KJ/m |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Load bending temperature | | D648 | 199(217) | °C |
Flame retardancy | | UL94 | HB | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Insulation strength | | IEC 243-1 | 27 | MV/m |
Dielectric loss factor | | IEC 250 | 0.013(0.023) | |
Dielectric constant | | D150 | 4 | Pf/m |
Arc track resistance | | IEC 112 | 500 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.