Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|
colour | | | Black | |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
elongation | | ASTM D-638 | 0.75 | % |
Flexural strength | | ASTM D-790 | 26.5 | Ksi |
tensile strength | | ASTM D-638 | 18.0 | Ksi |
compressive strength | | ASTM D-695 | 25.0 | Ksi |
Tensile modulus | | ASTM D-790 | 2.3 | Msi |
Elastic modulus | | ASTM D-638 | 2.5 | Msi |
IZOD impact strength | 1/8inch有缺 | ASTM D-256 | 1.1 | ft.lbf/in |
IZOD impact strength | 1/8inch无缺 | ASTM D-256 | 4.0 | ft.lbf/in |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Hot deformation temperature | | ASTM D-648 | >500 | °F |
Combustibility | | UL94 | V-0/5VA | |
UL Temperature Index | | UL | 200/220 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric constant | 1MHZ | ASTM D-150 | 4.6 | |
Loss factor | 1KHZ | ASTM D-150 | 0.058 | |
Loss factor | 1MHZ | ASTM D-150 | 0.0088 | |
Volume resistivity | | ASTM D-257 | 5×10 | Ω.m |
CTI Trace | | UL746A | 225 | V |
Dielectric constant number | 1KHZ | ASTM D-150 | 5.1 | |
Arc trace | | UL746A | 0 | in/min |
Insulation breakdown voltage | | ASTM D-149 | 450 | v/mil |
insulation resistance | 90℃ | | 1×10 | Ω |
Arc resistance | | ASTM D-495 | 167 | sec |
Basic performance | Test Condition | Test Method | Test Result | Unit |
---|
Melt index | | ASTM D-792 | 2.00 | g/10min |
Water absorption rate | | ASTM D-570 | 0.07 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.