Need Help? Contact Us service@plas.com
Get App

PPS DURAFIDE®  1140A7 JAPAN POLYPLASTIC

207
  • Properties:
    Flame retardant
    Glass fiber reinforced
    High mobility
    High temperature resistan
  • Usages:
    Electrical field
    Electrical appliances
    Electronic field
  • Certificates:
    SGS

Technical Data Sheet

Physical propertiesTest ConditionTest MethodTest ResultUnit
densityASTM D792/ISO 11831.66
Water absorption rate 23 ℃/24hASTM D570/ISO 620.01%
physical property Test ConditionTest MethodTest ResultUnit
Water absorption rate23°C,24hrISO620.040%
Melt viscosity310°C,1000sec^-1ISO11443160000mPa·s
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile stressISO527-2170Mpa
Tensile strain断裂ISO527-21.4%
Bending stressISO178240Mpa
tensile strength ASTM D638/ISO 527170kg/cm²(MPa)[Lb/in²]
Bending modulusASTM D790/ISO 17814000kg/cm²(MPa)[Lb/in²]
Bending modulusISO17814000Mpa
bending strength ASTM D790/ISO 178240kg/cm²(MPa)[Lb/in²]
Tensile elongation at break (elongation at break)ASTM D638/ISO 5271.4%
Thermal performanceTest ConditionTest MethodTest ResultUnit
Combustibility (rate)UL94V-0
Hot deformation temperature1.8MPa,未退火ISO75-2/A275°C
Linear coefficient of thermal expansionTD内部方法4E-05cm/cm/°C
Linear coefficient of thermal expansionMD内部方法1E-05cm/cm/°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Volume resistivityIEC600934E+15ohms·cm
Volume resistivityASTM D257/IEC 600934.0 x 10^15Ω.cm
Dielectric strength3.00mmIEC60243-115KV/mm
Relative permittivity1kHzIEC602504.30
Relative permittivity1MHzIEC602504.30
Leakage Trace IndexIEC60112125V
Dissipation factor1kHzIEC602501E-03
Dissipation factor1MHzIEC602502E-03
Dissipation factor耐电弧性IEC60250124sec
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell hardnessM级ISO2039-2105
flammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant ratingUL94V-0
Supplementary InformationTest ConditionTest MethodTest ResultUnit
ColourNumberHF2000/HD9050
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.