Technical Data Sheet
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Melt flow rate | 300°C/1.2 kg | ASTM D1238 | 7.0 | g/10 min |
Shrinkage rate - flow | | ASTM D955 | 0.50 到 0.70 | % |
Density/specific gravity | | ASTM D792 | 1.20 | g/cm³ |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Bending modulus 4 | | ASTM D790 | 2350 | Mpa |
elongation | 断裂 | ASTM D638 | > 100 | % |
bending strength | 屈服 | ASTM D790 | 90.2 | Mpa |
Tensile strength | 屈服 | ASTM D638 | 61.8 | Mpa |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Vicat softening temperature | | ASTM D15255 | 153 | °C |
Thermal deformation temperature under load | 0.45 MPa, 未退火 | ASTM D648 | 144 | °C |
Thermal deformation temperature under load | 1.8 MPa, 未退火 | ASTM D648 | 133 | °C |
injection | Test Condition | Test Method | Test Result | Unit |
---|
drying time | | | 4.0 | hr |
Temperature at the rear of the barrel | | | 290 到 310 | °C |
Temperature in the middle of the barrel | | | 280 到 300 | °C |
Temperature at the front of the material cylinder | | | 270 到 290 | °C |
Spray nozzle temperature | | | 280 到 300 | °C |
drying temperature | | | 120 | °C |
Suggested maximum moisture content | | | 0.020 | % |
Processing (melt) temperature | | | 290 到 310 | °C |
Mold temperature | | | 60 到 90 | °C |
Hopper temperature | | | 60 到 80 | °C |
Suggested maximum recycled material ratio | | | 20 | % |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of cantilever beam gap | 23°C, 3.18 mm | ASTM D256 | 830 | J/m |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
transmissivity | | ASTM D1003 | 89.0 | % |
Haze | | ASTM D1003 | < 0.80 | % |
Refractive index | | ASTM D542 | 1.585 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.