Need Help? Contact Us service@plas.com
Get App

PPO NORYL™  GFN3 SABIC INNOVATIVE US

310
  • Properties:
    enhance
    Glass fiber reinforced
    Hydrolysis resistance
  • Usages:
    Lawn equipment
    Electrical field
    Electrical appliances
    Electronic field
    Lighting fixtures
    Engine hood parts
    Non specific food
    Nursing supplies
    Architectural application
    Automotive External Parts
    Outdoor applications
    Liquid handling
    Medical supplies
    Garden equipment
    Lighting applications
  • Certificates:
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Water absorption rate, 24 hours @ 73FASTM D-5700.060%
Density, SolidASTM D-7921.28
Mold shrinkage, flow, 0.125"ASTM D-9551-4in/in E-3
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Hardness, Rockwell LASTM D-785108
Izod impact value, gap- 40FASTM D-2561.8ft-lb/in
Izod impact value, gap, 73FASTM D-2562.2ft-lb/in
Stretching elongation, fracture, type I 0.125“ASTM D-6385.0%
Tensile strength, yield, type I, 0.125“ASTM D-63815000psi
Flexural strength, yield, 0.250“ASTM D-79023500psi
Flexural modulus, 0.250“ASTM D 7901040000psi
CTE (coefficient of thermal expansion), flow, -40F ~ 200FASTM E-8311E-05in/in-F
Thermal performanceTest ConditionTest MethodTest ResultUnit
HDT (Heat Distortion Temperature), 264 psi, 0.250 ", unannealedASTM D-648280deg F
UL file number, United StatesE121562
Thermal index, non mechanical impact performanceUL 746B90deg C
Rated HB value测试厚度CSA LISTEDLS8840文档号
HDT (Heat Distortion Temperature), 66 psi, 0.250 ", unannealedASTM D-648317deg F
Thermal index, mechanical impact performanceUL 746B90deg C
Thermal index, electrical performanceUL 746B90deg C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dielectric constant, 60 HzASTM D-1502.93
Dielectric strength, in oil, 125 milsASTM D-149550v/mil
Loss factor, 60 HzASTM D-1500.0009
Other performanceTest ConditionTest MethodTest ResultUnit
Oxygen indexLOIASTM D-286326.0%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.