Need Help? Contact Us service@plas.com
Get App

ABS/PC CYCOLOY™  C2950-701NSDD SABIC INNOVATIVE US

630
  • Properties:
    Flame retardant
    High mobility
    High impact resistance
    High temperature resistan
    heat-resisting
  • Usages:
    Electrical field
    Electronic field
    Household appliances
    Automotive sector

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Melt Mass Flow Rate (MFR) 260 ° C/2.16 kgASTM D123810g/10min
Longitudinal shrinkage rate (Flow)flow, 3.2 Internal0.4~0.8
Longitudinal shrinkage rate (Flow)xflow, 3.2Internal0.4~0.6
Water absorption rateflow, 3.2 ASTM D5700.4
Water absorption rate24 hoursASTM D5700.1
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile strength yield (yld)Type I, 50ASTM D63862
Tensile elongation fracture (brk)Type I, 50ASTM D63840
Bending strength yield (yld)2.6 mm/ASTM D790102
Bending modulus2.6 mm/ASTM D7902650
combustion performanceTest ConditionTest MethodTest ResultUnit
UL fire rating V-0UL941.5
UL fire rating 5VBUL942.49
Oxygen Index (LOI)ASTM D 286332%
Impact performanceTest ConditionTest MethodTest ResultUnit
Izod Notched -30 ℃ (-22 ℉)ASTM D256160
Izod Notched at 23 ℃ (73 ℉)ASTM D256534
Instrumented dart impact energy -30 ℃ (-22 ℉) peakASTM D376354 
Instrumented dart impact energy 23 ℃ (73 ℉) total energyASTM D376361 
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell hardness RASTM D785123R
Electrical performanceTest ConditionTest MethodTest ResultUnit
Volume resistivityASTM D257100000000000000000ohm-cm
Surface resistivityASTM D25710000000000000000Ohm
Dielectric constant (DK) 50/60 HzASTM D 150
Dielectric constant (DK) 100HzASTM D 150
Dissipation factor (DF) 50/60 HzASTM D 15050E-4
Dissipation factor (DF) 100HzASTM D 15049E-4
Compared to the Leakage Traceability Index (CTI)UL 746A0plc
Insulation strengthin oil, 3.2 ASTM D14919.5
Arc resistance6plc
High Voltage Arc Traceability Rate (HVTR)UL 746A2plc
Hot wire ignition (HWI)UL 746A1plc
High current arc ignition (HAI)UL 746A0plc
Thermal Properties Test ConditionTest MethodTest ResultUnit
Vicat softening temperatureRate B/50ASTM D152585°C
Relative Temperature Index (RTI) impact w/impact-UL 746B85°C
Relative Temperature Index (RTI) Electrical Elec-UL 746B85°C
Relative Temperature Index (RTI) intensity w/o impact-UL 746B85°C
Coefficient of Linear Expansion (CLTE) Longitudinal (Flow)-30°C to 3ASTM E83172E-6/°C
Coefficient of Linear Expansion (CLTE) Across Flow-30°C to 3ASTM E83172E-6/°C
thermal conductivityASTM C 1770.2 W/m-°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.