POM Delrin® 100AL NC010 DUPONT USA

381
  • Properties:
    High rigidity
    High hardness
    Thermal stability
    high viscosity
    heat-resisting
  • Usages:
    Thin walled products
    packing
  • Certificates:
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Shrinkage rateTDISO294-41.8%
Shrinkage rateMDISO294-42.0%
Melt mass flow rate190°C/2.16kgISO11332.5g/10min
Density/specific gravityISO11831.40g/cm³
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile creep modulus1000hrISO899-11500Mpa
Tensile stress屈服ISO527-270.0Mpa
Tensile strain屈服ISO527-218%
Tensile modulusISO527-23000Mpa
Bending modulusISO1782800Mpa
TensileCreepModule1hrISO899-12700Mpa
Nominal tensile fracture strainISO527-245%
Thermal performanceTest ConditionTest MethodTest ResultUnit
Hot deformation temperature0.45MPa,未退火ISO75-2/B163°C
Hot deformation temperature1.8MPa,未退火ISO75-2/A97.0°C
Melting temperature 2ISO11357-3178°C
Linear coefficient of thermal expansionMDISO11359-21.1E-04cm/cm/°C
Linear coefficient of thermal expansionTDISO11359-21.1E-04cm/cm/°C
AnnealingTemperature160°C
AnnealingTime-Optional30.0min/mm
Impact performanceTest ConditionTest MethodTest ResultUnit
Charpy Notched Impact Strength -30°CISO179/1eA7.0kJ/m²
Charpy Notched Impact Strength 23°CISO179/1eA9.0kJ/m²
Impact strength of cantilever beam gap23°CISO180/1A8.0kJ/m²
Impact strength of simply supported beam without notch-30°CISO179/1eU170kJ/m²
Impact strength of simply supported beam without notch23°CISO179/1eU250kJ/m²
flammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant rating0.8mmUL94HB
UL flame retardant rating1.5mmUL94HB
UL flame retardant rating0.8mmIEC60695-11-10,-20HB
UL flame retardant rating1.5mmIEC60695-11-10,-20HB
FMVSS flammabilityFMVSS302B
Fogging-G-valuecondensateISO64521E-04g
Burning rate 31.00mmISO379526mm/min
Supplementary InformationTest ConditionTest MethodTest ResultUnit
EmissionVDA275<8.00mg/kg
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.