Need Help? Contact Us service@plas.com
Get App

PEI ULTEM™  2200 SABIC INNOVATIVE US

339
  • Properties:
    Glass fiber reinforced
    Food contact compliance
    Creep resistance
  • Usages:
    Electronic and electrical
  • Certificates:
    UL

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Shrinkage rateMD:3.20mm内部方法0.30to0.50%
Water absorption rate24hrASTMD5700.19%
Water absorption rate平衡,23°CASTMD5701.1%
Melt mass flow rate337°C/6.6kgASTMD12386.0g/10min
Density/specific gravityASTMD7921.42g/cm³
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Flexural Strength4Break,100mmSpanASTMD790228Mpa
Tensile modulus 2ASTMD6386890Mpa
Tensile strength 3断裂ASTMD638131Mpa
Bending modulus 4100mmSpanASTMD7906890Mpa
Elongation rate 4断裂ASTMD6384.0%
Thermal performanceTest ConditionTest MethodTest ResultUnit
Linear coefficient of thermal expansionMD:-20to150°CASTME8312.5E-05cm/cm/°C
Vicat softening temperatureASTMD15255220°C
Hot deformation temperature0.45MPa,未退火,6.40mmASTMD648210°C
Hot deformation temperature1.8MPa,未退火,6.40mmASTMD648210°C
RTIElecUL746170°C
Evolution Calendar intelligent importerUL746170°C
RTIStrUL746170°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Dissipation factor1kHzASTMD1501.5E-03
Dissipation factor2.45GHzASTMD1504.9E-03
Dielectric constant1kHzASTMD1503.50
Volume resistivityASTMD2577E+16ohms·cm
Compared to the anti leakage trace indexCTIUL746PLC4
Arc resistance 6ASTMD495PLC6
High arc combustion indexHAIUL746PLC4
High voltage arc tracing rateHVTRUL746PLC2
Dielectric strength1.60mm,inOilASTMD14926KV/mm
Hot wire ignitionHWIUL746PLC1
Impact performanceTest ConditionTest MethodTest ResultUnit
ReverseNotchIzodImpact3.20mmASTMD256460J/m
Impact strength of cantilever beam gap23°CASTMD25664J/m
Impact strength of cantilever beam gap23°CASTMD4812480J/m
hardnessTest ConditionTest MethodTest ResultUnit
Rockwell hardnessM级ASTMD785114
flammabilityTest ConditionTest MethodTest ResultUnit
Extreme Oxygen IndexASTMD286350%
UL flame retardant rating0.41mmUL94V-0
UL flame retardant rating1.9mmUL945VA
NBSSmokeDensity-Flaming,Ds,4minASTME6621.30
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.