Need Help? Contact Us service@plas.com
Get App

ABS/PC CYCOLOY™  CX7240-7M1D218 SABIC INNOVATIVE NANSHA

612
  • Properties:
    Flame retardant
    High impact resistance
    High mobility
  • Usages:
    Electrical field
    Electronic field
    Electronic display
    Engine hood parts
    Aerospace Applications
    Nursing supplies
    Construction field
    Outdoor applications
    Liquid handling
    Medical supplies
    Lighting fixtures

Technical Data Sheet

physical property Test ConditionTest MethodTest ResultUnit
Melt flow rate260°C/2.16 kgASTM D123818g/10 min
Molten Volume Flow Rate (MVR)260°C/2.16 kgISO 113315.0cm3/10min
Shrinkage rate - flow3.20 mm内部方法0.40 到 0.60%
Water absorption rate饱和, 23°CISO 620.20%
Water absorption rate平衡, 23°C, 50% RHISO 620.10%
Mechanical performanceTest ConditionTest MethodTest ResultUnit
Tensile modulus-- 2ASTM D6382600Mpa
Tensile modulus--ISO 527-2/12600Mpa
Tensile strength屈服 3ASTM D63865.0Mpa
Tensile strength屈服ISO 527-2/5065.0Mpa
Tensile strength断裂 3ASTM D63858.0Mpa
Tensile strength断裂ISO 527-2/5050.0Mpa
elongation屈服 3ASTM D6384.1%
elongation屈服ISO 527-2/504.0%
elongation断裂 3ASTM D638100%
elongation断裂ISO 527-2/5090%
Bending modulus50.0 mm 跨距 4ASTM D7902500Mpa
Bending modulus-- 5ISO 1782500Mpa
Bending stress-- 5, 6ISO 17896.0Mpa
Bending stress屈服, 50.0 mm 跨距 4ASTM D790104Mpa
Thermal performanceTest ConditionTest MethodTest ResultUnit
Thermal deformation temperature under load0.45 MPa, 未退火, 3.20 mmASTM D648100°C
Thermal deformation temperature under load1.8 MPa, 未退火, 3.20 mmASTM D64889.0°C
Thermal deformation temperature under load1.8 MPa, 未退火, 6.40 mmASTM D64899.0°C
Thermal deformation temperature under load1.8 MPa, 未退火, 4.00 mm, 64.0 mm 跨距 10ISO 75-2/Af93.0°C
Vicat softening temperature--ASTM D152511, ISO 306/B5011110°C
Vicat softening temperature--ISO 306/B120113°C
Ball Pressure Test73 到 77°CIEC 60695-10-2通过
Linear coefficient of thermal expansion流动 : -40 到 40°CASTM E831, ISO 11359-27.5E-5cm/cm/°C
Linear coefficient of thermal expansion横向 : -40 到 40°CASTM E8317.5E-5cm/cm/°C
Linear coefficient of thermal expansion横向 : -40°CISO 11359-27.5E-5cm/cm/°C
thermal conductivityISO 83020.20W/m/K
RTI ElecUL 74690.0°C
RTI ImpUL 74690.0°C
RTIUL 74690.0°C
Electrical performanceTest ConditionTest MethodTest ResultUnit
Surface resistivityIEC 60093> 1.0E+15ohms
Volume resistivityIEC 60093> 1.0E+15ohms·cm
Dielectric strength0.800 mm, 在油中IEC 60243-135KV/mm
Dielectric strength1.60 mm, 在油中IEC 60243-125KV/mm
Dielectric strength3.20 mm, 在油中IEC 60243-117KV/mm
Compared to the Leakage Tracking Index (CTI)UL 746PLC 3
High arc combustion index (HAI) 12UL 746PLC 0
Hot wire ignition (HWI)UL 746PLC 3
injectionTest ConditionTest MethodTest ResultUnit
drying temperature80 到 90°C
drying time2.0 到 4.0hr
Suggested maximum moisture content0.020%
Hopper temperature60 到 80°C
Temperature at the rear of the barrel230 到 280°C
Temperature in the middle of the barrel240 到 290°C
Temperature at the front of the material cylinder250 到 300°C
Spray nozzle temperature250 到 300°C
Processing (melt) temperature250 到 300°C
Mold temperature60 到 85°C
Exhaust hole depth0.030 到 0.075mm
Impact performanceTest ConditionTest MethodTest ResultUnit
Dart impact equipped with measuring instruments23°C, Total EnergyASTM D376365.0J
flammabilityTest ConditionTest MethodTest ResultUnit
UL flame retardant rating0.60 mmUL 94V-1
UL flame retardant rating0.75 mmUL 94V-0
UL flame retardant rating1.5 mmUL 945VB
UL flame retardant rating3.0 mmUL 945VA
Burning wire flammability index0.75 mmIEC 60695-2-12960°C
Burning wire flammability index0.75 mm 13IEC 60695-2-12960°C
Hot filament ignition temperature0.75 mm 13IEC 60695-2-13775°C
Hot filament ignition temperature1.0 mmIEC 60695-2-13825°C
Hot filament ignition temperature1.5 mm 13IEC 60695-2-13775°C
Hot filament ignition temperature3.0 mmIEC 60695-2-13800°C
Hot filament ignition temperature3.0 mm 13IEC 60695-2-13775°C
Extreme Oxygen IndexISO 4589-234%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.