Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
ABS HD M203FC BASF GERMANY
Novodur® 
Shell、Medical/nursing supplies、Medical supplies
Good disinfection perform、High mobility
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
ABS/BASF GERMANY/HD M203FC
Melt volume flow rate
220°C/10.0kg
ISO1133
cm3/10min
3
Shrinkage rate
ISO294-4
%
0
Mechanical performance
Test Condition
Test Method
Unit
ABS/BASF GERMANY/HD M203FC
Tensile modulus
ISO527-2
Mpa
2
Tensile strain
屈服,23°C
ISO527-2
%
2
Tensile strain
断裂,23°C
ISO527-2
%
>
Tensile stress
屈服,23°C
ISO527-2
Mpa
4
Ball pressure hardness
ISO2039-1
Mpa
1
Bending modulus
ISO178
Mpa
2
Bending stress
ISO178
Mpa
7
Thermal performance
Test Condition
Test Method
Unit
ABS/BASF GERMANY/HD M203FC
Hot deformation temperature 2
0.45MPa,Annealed
ISO75-2/B
°C
9
Hot deformation temperature 2
1.8MPa,退火
ISO75-2/A
°C
9
Vicat softening temperature
ISO306/B50
°C
9
Linear coefficient of thermal expansion
MD
ISO11359-2
cm/cm/°C
9
Electrical performance
Test Condition
Test Method
Unit
ABS/BASF GERMANY/HD M203FC
Electrical strength
1.50mm
IEC60243-1
KV/mm
3
Surface resistivity
IEC60093
ohms
>
Leakage Trace Index
IEC60112
V
6
Volume resistivity
IEC60093
ohms·cm
>
Impact performance
Test Condition
Test Method
Unit
ABS/BASF GERMANY/HD M203FC
Impact strength of simply supported beam without notch
-30°C
ISO179
kJ/m²
9
Impact strength of simply supported beam without notch
23°C
ISO179
kJ/m²
1