Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA6T C240 MITSUI CHEM JAPAN
ARLEN™ 
Electrical field、Electronic field
Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
PA6T/MITSUI CHEM JAPAN/C240
Mold shrinkage rate
2mmt
ASTM D-955
%
0
Mechanical performance
Test Condition
Test Method
Unit
PA6T/MITSUI CHEM JAPAN/C240
IZOD notch impact strength
dry(moist)
ASTM D-256
J/m
8
tensile strength
dry(moist)
ASTM D-638
Mpa
2
tensile elongation
dry(moist)
ASTM D-638
%
3
Rockwell hardness
ASTM D-785
M Scale
1
Bending modulus
dry(moist)
ASTM D-790
Mpa
1
bending strength
dry(moist)
ASTM D-790
Mpa
3
Thermal performance
Test Condition
Test Method
Unit
PA6T/MITSUI CHEM JAPAN/C240
Load deflection temperature
ASTM D-648
°C
3
Electrical performance
Test Condition
Test Method
Unit
PA6T/MITSUI CHEM JAPAN/C240
Dielectric breakdown voltage
dry
ASTM D-149
KV/mm
3
Volume resistivity
dry
ASTM D-257
Ω.cm
1
Basic performance
Test Condition
Test Method
Unit
PA6T/MITSUI CHEM JAPAN/C240
Water absorption rate
23℃,24小时在水里(2mmt,100℃)
ASTM D-570
%
0