Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC 303-15 STYRON US
CALIBRE™
Electrical field、Electronic field
UV resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
physical property
Test Condition
Test Method
Unit
PC/STYRON US/303-15
Density/specific gravity
ISO1183/B
g/cm³
1
Melt mass flow rate
300°C/1.2kg
ISO1133
g/10min
1
Shrinkage rate
MD
ISO294-4
%
0
Water absorption rate
23°C,24hr
ISO62
%
0
Water absorption rate
平衡,23°C,50%RH
ISO62
%
0
Mechanical performance
Test Condition
Test Method
Unit
PC/STYRON US/303-15
Tensile modulus
ISO527-2/50
Mpa
2
Tensile strain
屈服
ISO527-2/50
%
6
Tensile strain
断裂
ISO527-2/50
%
1
Tensile stress
屈服
ISO527-2/50
Mpa
6
Tensile stress
断裂
ISO527-2/50
Mpa
7
Taber abraser
ISO9352
%
4
Bending modulus 2
ISO178
Mpa
2
Bending stress 2
ISO178
Mpa
9
Thermal performance
Test Condition
Test Method
Unit
PC/STYRON US/303-15
Ball pressure temperature
IEC60335-1
°C
>
Hot deformation temperature
1.8MPa,退火
ISO75-2/A
°C
1
Hot deformation temperature
0.45MPa,退火
ISO75-2/B
°C
1
Hot deformation temperature
1.8MPa,未退火
ISO75-2/A
°C
1
Vicat softening temperature
ISO306/B50
°C
1
Linear coefficient of thermal expansion
MD
ISO11359-2
cm/cm/°C
7
Electrical performance
Test Condition
Test Method
Unit
PC/STYRON US/303-15
Dielectric strength
IEC60243-1
KV/mm
1
Volume resistivity
IEC60093
ohms·cm
>
Compared to the anti leakage trace index
2.00mm,SolutionA
IEC60112
V
2
Impact performance
Test Condition
Test Method
Unit
PC/STYRON US/303-15
Charpy Notched Impact Strength
-30°C
ISO179/1eA
kJ/m²
1
Charpy Notched Impact Strength
23°C
ISO179/1eA
kJ/m²
2
Impact strength of cantilever beam gap
23°C
ISO180/A
kJ/m²
8
flammability
Test Condition
Test Method
Unit
PC/STYRON US/303-15
GlowWireFlammability Index3
1.0mm
IEC60695-2-12
°C
9
GlowWireFlammability Index3
2.0mm
IEC60695-2-12
°C
8
GlowWireFlammability Index3
3.0mm
IEC60695-2-12
°C
8
Extreme Oxygen Index 3
ISO4589-2
%
2
Hot filament ignition temperature 3
3.0mm
IEC60695-2-13
°C
7
Hot filament ignition temperature 3
1.0mm
IEC60695-2-13
°C
8
Hot filament ignition temperature 3
2.0mm
IEC60695-2-13
°C
7
optical performance
Test Condition
Test Method
Unit
PC/STYRON US/303-15
transmissivity
ASTMD1003
%
8
Haze
ASTMD1003
%
1