Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PP RPP 2000 A SCHULMAN USA
POLYFORT®
--
Halogen-free
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
physical property
Test Condition
Test Method
Unit
PP/A SCHULMAN USA/RPP 2000
Melt volume flow rate
230°C/2.16kg
ISO1133
cm3/10min
8
Mechanical performance
Test Condition
Test Method
Unit
PP/A SCHULMAN USA/RPP 2000
Tensile modulus
ISO527-2/1A/1
Mpa
1
Tensile strain
屈服
ISO527-2/1A/50
%
8
Tensile stress
屈服
ISO527-2/1A/50
Mpa
3
Thermal performance
Test Condition
Test Method
Unit
PP/A SCHULMAN USA/RPP 2000
RTIElec
0.75mm
UL746
°C
6
RTIElec
3.0mm
UL746
°C
6
RTIElec
1.5mm
UL746
°C
6
Evolution Calendar intelligent importer
3.0mm
UL746
°C
6
Evolution Calendar intelligent importer
1.5mm
UL746
°C
6
Evolution Calendar intelligent importer
0.75mm
UL746
°C
6
RTIStr
3.0mm
UL746
°C
6
RTIStr
1.5mm
UL746
°C
6
RTIStr
0.75mm
UL746
°C
6
Hot deformation temperature
0.45MPa,未退火
ISO75-2/Bf
°C
1
Hot deformation temperature
1.8MPa,未退火
ISO75-2/Af
°C
5
Vicat softening temperature
--
ISO306/A50
°C
1
Vicat softening temperature
--
ISO306/B50
°C
9
Electrical performance
Test Condition
Test Method
Unit
PP/A SCHULMAN USA/RPP 2000
Leakage Trace Index
IEC60112
V
6
Impact performance
Test Condition
Test Method
Unit
PP/A SCHULMAN USA/RPP 2000
Impact strength of simply supported beam without notch
-30°C
ISO179/1eU
kJ/m²
1
flammability
Test Condition
Test Method
Unit
PP/A SCHULMAN USA/RPP 2000
Extreme Oxygen Index
ISO4589-2
%
2
Burning rate
3.00mm,自动灭火
ISO3795
mm/min
0
Burning rate
1.50mm,自动灭火
ISO3795
mm/min
0
Burning rate
0.750mm,Self-Extinguishing
ISO3795
mm/min
0
Hot filament ignition temperature
3.0mm
IEC60695-2-13
°C
7
Hot filament ignition temperature
1.5mm
IEC60695-2-13
°C
7
Hot filament ignition temperature
0.75mm
IEC60695-2-13
°C
7
Burning wire flammability index
3.0mm
IEC60695-2-12
°C
9
Burning wire flammability index
1.5mm
IEC60695-2-12
°C
9
Burning wire flammability index
0.75mm
IEC60695-2-12
°C
9