Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PPA AT-1002 HS SOLVAY USA
AMODEL® 
Industrial applications、Automotive Applications
High temperature resistan、Thermal stability
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
PPA/SOLVAY USA/AT-1002 HS
Shrinkage rate
TD
ASTMD955
%
2
Shrinkage rate
MD
ASTMD955
%
2
Water absorption rate
24hr
ASTMD570
%
0
Mechanical performance
Test Condition
Test Method
Unit
PPA/SOLVAY USA/AT-1002 HS
shear strength
ASTMD732
Mpa
6
Tensile strength
ASTMD638
Mpa
8
Tensile modulus
23°C
ISO527-2
Mpa
2
Tensile modulus
100°C
ISO527-2
Mpa
2
Tensile modulus
ASTMD638
Mpa
2
Tensile strain
屈服,23°C
ISO527-2
%
5
Tensile strain
Yield,100°C
ISO527-2
%
3
Tensile strain
断裂,23°C
ISO527-2
%
1
Tensile stress
屈服,23°C
ISO527-2
Mpa
7
Tensile stress
Yield,100°C
ISO527-2
Mpa
3
Tensile stress
断裂,23°C
ISO527-2
Mpa
6
Elongation rate 2
断裂
ASTMD638
%
8
Bending modulus
ASTMD790
Mpa
2
Bending modulus
23°C
ISO178
Mpa
2
Bending modulus
100°C
ISO178
Mpa
1
bending strength
ASTMD790
Mpa
1
Bending stress
23°C
ISO178
Mpa
7
Bending stress
100°C
ISO178
Mpa
4
Thermal performance
Test Condition
Test Method
Unit
PPA/SOLVAY USA/AT-1002 HS
Hot deformation temperature
1.8MPa,退火
ASTMD648
°C
1
Hot deformation temperature
1.8MPa,未退火
ISO75-2/Af
°C
1
Hot deformation temperature
0.45MPa,退火
ASTMD648
°C
1
Peak melting temperature
ASTMD3418
°C
3
Melting temperature
ISO11357-3
°C
3
Linear coefficient of thermal expansion
MD:0to100°C
ASTME831
cm/cm/°C
7
Linear coefficient of thermal expansion
TD:100到200°C
ASTME831
cm/cm/°C
1
Linear coefficient of thermal expansion
TD:0to100°C
ASTME831
cm/cm/°C
9
Linear coefficient of thermal expansion
MD:100到200°C
ASTME831
cm/cm/°C
1
Electrical performance
Test Condition
Test Method
Unit
PPA/SOLVAY USA/AT-1002 HS
Surface resistivity
ASTMD257
ohms
8
High voltage arc tracing rate
HVTR
UL746
mm/min
1
Dielectric strength
ASTMD149
KV/mm
1
Leakage Trace Index
ASTMD3638
V
>
Volume resistivity
ASTMD257
ohms·cm
1
Impact performance
Test Condition
Test Method
Unit
PPA/SOLVAY USA/AT-1002 HS
PenetrationImpact3
ASTMD3763
N
4
Dart impact equipped with measuring instruments
TotalEnergy
ASTMD3763
J
5