Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA66 K224-G6 DSM HOLAND
Akulon® 
wheel、furniture、Insulation material、Shell
Glass fiber reinforced、Filler: Glass fiber reinf、30%、Filler by weight
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K224-G6
Shrinkage rate
MD
ISO294-4
%
0
Shrinkage rate
TD
ISO294-4
%
0
Water absorption rate
饱和,23°C
ISO62
%
6
Water absorption rate
平衡,23°C,50%RH
ISO62
%
1
Mechanical performance
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K224-G6
Tensile modulus
ISO527-2
Mpa
9
Tensile strain
断裂
ISO527-2
%
3
Tensile stress
断裂
ISO527-2
Mpa
1
Bending modulus
ISO178
Mpa
8
Bending stress
ISO178
Mpa
2
Thermal performance
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K224-G6
Hot deformation temperature
0.45MPa,未退火
ISO75-2/B
°C
2
Hot deformation temperature
1.8MPa,未退火
ISO75-2/A
°C
2
Melting temperature 2
ISO11357-3
°C
2
Linear coefficient of thermal expansion
MD
ISO11359-2
cm/cm/°C
2
Linear coefficient of thermal expansion
TD
ISO11359-2
cm/cm/°C
7
Electrical performance
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K224-G6
Surface resistivity
IEC60093
ohms
-
Dielectric strength
IEC60243-1
KV/mm
3
Leakage Trace Index
IEC60112
V
-
Volume resistivity
IEC60093
ohms·cm
1
Impact performance
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K224-G6
Impact strength of simply supported beam without notch
-30°C
ISO179/1eU
kJ/m²
7
Impact strength of simply supported beam without notch
23°C
ISO179/1eU
kJ/m²
9
flammability
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K224-G6
Hot filament ignition temperature
2.0mm
IEC60695-2-13
°C
7
Hot filament ignition temperature
1.5mm
IEC60695-2-13
°C
7
Burning wire flammability index
1.5mm
IEC60695-2-12
°C
7
Burning wire flammability index
2.0mm
IEC60695-2-12
°C
7