Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PPA HTM-4H1 EMS-CHEMIE SWITZERLAND
Grivory® 
household electrical appl、Automotive interior parts
Low warpage、Chemical resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
PPA/EMS-CHEMIE SWITZERLAND/HTM-4H1
Mold shrinkage rate
trans,dry
ISO 294
%
0
Mold shrinkage rate
long,dry
ISO 294
%
0
Mechanical performance
Test Condition
Test Method
Unit
PPA/EMS-CHEMIE SWITZERLAND/HTM-4H1
impact strength
Charpy,23℃,dry(cond)
ISO 179/1eU
KJ/m
5
impact strength
Charpy,-30℃,dry(cond)
ISO 179/1eU
KJ/m
2
elongation at break
5mm/min,dry(cond)
ISO 527
%
1
Tensile fracture strength
5mm/min,dry(cond)
ISO 527
Mpa
1
Gap impact strength
Charpy,-30℃,dry(cond)
ISO 179/1eA
KJ/m
3
Gap impact strength
Charpy,23℃,dry(cond)
ISO 179/1eA
KJ/m
5
hardness
dry(cond)
ISO 2039-1
Mpa
2
Thermal performance
Test Condition
Test Method
Unit
PPA/EMS-CHEMIE SWITZERLAND/HTM-4H1
Hot deformation temperature
1.80MPa,dry
ISO 75
°C
1
Hot deformation temperature
8.00MPa,dry
ISO 75
°C
1
Hot deformation temperature
0.45MPa,dry
ISO 75
°C
2
melting point
dry
ISO 11357
°C
3
Flame retardancy
0.8mm
ISO 1210
rating
H
Maximum operating temperature
short term,dry
ISO 2578
°C
2
Maximum operating temperature
long term,dry
ISO 2578
°C
1
Electrical performance
Test Condition
Test Method
Unit
PPA/EMS-CHEMIE SWITZERLAND/HTM-4H1
Surface resistivity
cond
IEC 60093
Ω
1
Dielectric strength
dry(cond)
IEC 60243-1
KV/mm
3
tracking resistance
cond
IEC 60112
V
5
Volume resistivity
dry(cond)
IEC 60093
Ω.cm
1
Basic performance
Test Condition
Test Method
Unit
PPA/EMS-CHEMIE SWITZERLAND/HTM-4H1
density
dry
ISO 1183
g/cm
1
Hygroscopicity
23℃/50%rh
ISO 62
%
1
Water absorption
23℃/sat
ISO 62
%
3
Other performance
Test Condition
Test Method
Unit
PPA/EMS-CHEMIE SWITZERLAND/HTM-4H1
Tensile modulus
1mm/min,dry(cond)
ISO 527
Mpa
7