Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6T FR52G45NHF DUPONT USA
Zytel®
electrical equipment、household electrical appl、Automotive interior parts
Dimensional stability、Low water absorption、Heat aging、high strength、High rigidity
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
physical property
Test Condition
Test Method
Unit
PA6T/DUPONT USA/FR52G45NHF
Shrinkage rate
横向流量
ISO 294-4
%
0
Shrinkage rate
流量
ISO 294-4
%
0
Mechanical performance
Test Condition
Test Method
Unit
PA6T/DUPONT USA/FR52G45NHF
Tensile modulus
ISO 527-2
Mpa
1
Tensile strain
断裂
ISO 527-2
%
1
Tensile stress
断裂
ISO 527-2
Mpa
1
Bending modulus
ISO 178
Mpa
1
Bending stress
ISO 178
Mpa
2
Thermal performance
Test Condition
Test Method
Unit
PA6T/DUPONT USA/FR52G45NHF
RTI Elec
0.40 mm
UL 746
°C
1
RTI Elec
0.75 mm
UL 746
°C
1
RTI Elec
1.5 mm
UL 746
°C
1
RTI Elec
3.0 mm
UL 746
°C
1
Hot deformation temperature
1.8 MPa, 未退火
ISO 75-2/A
°C
2
Melting temperature 3
ISO 11357-3
°C
3
Linear coefficient of thermal expansion
流动
ISO 11359-2
cm/cm/°C
1
Linear coefficient of thermal expansion
流动 : -40 到 23°C
ISO 11359-2
cm/cm/°C
1
Linear coefficient of thermal expansion
流动 : 55 到 160°C
ISO 11359-2
cm/cm/°C
1
Linear coefficient of thermal expansion
横向
ISO 11359-2
cm/cm/°C
5
Linear coefficient of thermal expansion
横向 : -40 到 23°C
ISO 11359-2
cm/cm/°C
4
Linear coefficient of thermal expansion
横向 : 55 到 160°C
ISO 11359-2
cm/cm/°C
8
Electrical performance
Test Condition
Test Method
Unit
PA6T/DUPONT USA/FR52G45NHF
Dielectric strength
IEC 60243-1
KV/mm
4
Leakage Trace Index
IEC 60112
V
6
Volume resistivity
IEC 62631-3-1
ohms·m
>
Impact performance
Test Condition
Test Method
Unit
PA6T/DUPONT USA/FR52G45NHF
Impact strength of simply supported beam without notch
-30°C
ISO 179/1eU
kJ/m²
4
Impact strength of simply supported beam without notch
23°C
ISO 179/1eU
kJ/m²
4
flammability
Test Condition
Test Method
Unit
PA6T/DUPONT USA/FR52G45NHF
Hot filament ignition temperature
0.40 mm
IEC 60695-2-13
°C
7
Hot filament ignition temperature
0.75 mm
IEC 60695-2-13
°C
7
Hot filament ignition temperature
1.5 mm
IEC 60695-2-13
°C
7
Hot filament ignition temperature
3.0 mm
IEC 60695-2-13
°C
8
Burning wire flammability index
0.40 mm
IEC 60695-2-12
°C
9
Burning wire flammability index
0.75 mm
IEC 60695-2-12
°C
9
Burning wire flammability index
1.5 mm
IEC 60695-2-12
°C
9
Burning wire flammability index
3.0 mm
IEC 60695-2-12
°C
9