Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PPA PA GF 60 NA AKRO-PLASTIC GERMANY
AKROLOY®
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
PPA/AKRO-PLASTIC GERMANY/PA GF 60 NA
Humidity Absorption - 62% RH
70°C
ISO 1110
%
0
Spiral Flow 2, 3
内部方法
CM
4
Shrinkage rate
横向流量
ISO 294-4
%
0
Shrinkage rate
流量
ISO 294-4
%
<
Water absorption rate
饱和, 23°C
ISO 62
%
3
Mechanical performance
Test Condition
Test Method
Unit
PPA/AKRO-PLASTIC GERMANY/PA GF 60 NA
Tensile modulus
ISO 527-2/1
Mpa
2
Tensile strain
断裂
ISO 527-2/5
%
2
Tensile stress
断裂
ISO 527-2/5
Mpa
2
Bending modulus 4
ISO 178
Mpa
2
Bending stress 4
ISO 178
Mpa
4
Thermal performance
Test Condition
Test Method
Unit
PPA/AKRO-PLASTIC GERMANY/PA GF 60 NA
Hot deformation temperature
0.45 MPa, 未退火
ISO 75-2/B
°C
2
Hot deformation temperature
1.8 MPa, 未退火
ISO 75-2/A
°C
2
Melting temperature 5
DIN EN 11357-1
°C
2
Linear coefficient of thermal expansion
流动 : 23 到 80°C
ISO 11359-2
cm/cm/°C
1
Linear coefficient of thermal expansion
横向 : 23 到 80°C
ISO 11359-2
cm/cm/°C
5
Electrical performance
Test Condition
Test Method
Unit
PPA/AKRO-PLASTIC GERMANY/PA GF 60 NA
Leakage Trace Index
解决方案 A
IEC 60112
V
6
Impact performance
Test Condition
Test Method
Unit
PPA/AKRO-PLASTIC GERMANY/PA GF 60 NA
Impact strength of simply supported beam without notch
-30°C
ISO 179/1eU
kJ/m²
9
Impact strength of simply supported beam without notch
23°C
ISO 179/1eU
kJ/m²
1
hardness
Test Condition
Test Method
Unit
PPA/AKRO-PLASTIC GERMANY/PA GF 60 NA
Ball pressure hardness
H 961/30
ISO 2039-1
Mpa
3
flammability
Test Condition
Test Method
Unit
PPA/AKRO-PLASTIC GERMANY/PA GF 60 NA
Reinforcement Content
ISO 1172
%
6
Burning rate
1.00 mm
FMVSS 302
mm/min
<
Hot filament ignition temperature
0.8 mm
IEC 60695-2-13
°C
6