Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA66 K225-KS DSM HOLAND
Akulon® 
Electrical field、Electronic field
Flame retardant、Halogen-free、Thermal stability
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K225-KS
Shrinkage rate
MD
ISO294-4
%
1
Shrinkage rate
TD
ISO294-4
%
0
Water absorption rate
饱和,23°C
ISO62
%
9
Water absorption rate
平衡,23°C,50%RH
ISO62
%
2
Mechanical performance
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K225-KS
Nominal tensile fracture strain
ISO527-2
%
8
Tensile modulus
ISO527-2
Mpa
3
Tensile strain
屈服
ISO527-2
%
3
Tensile stress
屈服
ISO527-2
Mpa
8
Thermal performance
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K225-KS
Hot deformation temperature
0.45MPa,未退火
ISO75-2/B
°C
1
Hot deformation temperature
1.8MPa,未退火
ISO75-2/A
°C
7
Melting temperature 2
ISO11357-3
°C
2
Linear coefficient of thermal expansion
MD
ISO11359-2
cm/cm/°C
9
Linear coefficient of thermal expansion
TD
ISO11359-2
cm/cm/°C
9
Electrical performance
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K225-KS
Surface resistivity
IEC60093
ohms
-
Dielectric strength
IEC60243-1
KV/mm
3
Leakage Trace Index
IEC60112
V
6
Volume resistivity
IEC60093
ohms·cm
>
Impact performance
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K225-KS
Impact strength of simply supported beam without notch
-30°C
ISO179/1eU
kJ/m²
5
Impact strength of simply supported beam without notch
23°C
ISO179/1eU
kJ/m²
6
flammability
Test Condition
Test Method
Unit
PA66/DSM HOLAND/K225-KS
Hot filament ignition temperature
0.38mm
IEC60695-2-13
°C
9
Hot filament ignition temperature
1.5mm
IEC60695-2-13
°C
9
Burning wire flammability index
0.38mm
IEC60695-2-12
°C
9
Burning wire flammability index
1.5mm
IEC60695-2-12
°C
9