Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PEI HU2200-1H1000 SABIC INNOVATIVE US
ULTEM™
packing、auto parts、medicine、Medical/nursing supplies
Flame retardant、Food contact、Filler: Glass fiber reinf、20%、Filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
physical property
Test Condition
Test Method
Unit
PEI/SABIC INNOVATIVE US/HU2200-1H1000
Melt volume flow rate
360°C/5.0kg
ISO1133
cm3/10min
7
Melt mass flow rate
337°C/6.6kg
ASTMD1238
g/10min
6
Shrinkage rate
MD:3.20mm
内部方法
%
0
Water absorption rate
饱和,23°C
ISO62
%
1
Water absorption rate
平衡,23°C,50%RH
ISO62
%
0
Mechanical performance
Test Condition
Test Method
Unit
PEI/SABIC INNOVATIVE US/HU2200-1H1000
Tensile strength 3
屈服
ASTMD638
Mpa
1
Tensile strength 3
断裂
ASTMD638
Mpa
1
Tensile modulus
ISO527-2/1
Mpa
6
Tensile modulus 2
ASTMD638
Mpa
6
Tensile strain
屈服
ISO527-2/5
%
4
Tensile strain
断裂
ISO527-2/5
%
4
Tensile stress
断裂
ISO527-2/5
Mpa
1
Tensile stress
屈服
ISO527-2/5
Mpa
1
Elongation rate 3
屈服
ASTMD638
%
4
Elongation rate 4
断裂
ASTMD638
%
4
Bending modulus 4
50.0mm跨距
ASTMD790
Mpa
6
Bending modulus 5
ISO178
Mpa
6
Bending strength 4
屈服,50.0mm跨距
ASTMD790
Mpa
2
Bending strength 5,6
ISO178
Mpa
2
Thermal performance
Test Condition
Test Method
Unit
PEI/SABIC INNOVATIVE US/HU2200-1H1000
Hot deformation temperature
1.8MPa,未退火,3.20mm
ASTMD648
°C
2
Hot deformation temperature 9
1.8MPa,Unannealed,100mmSpan
ISO75-2/Ae
°C
2
Vicat softening temperature
ASTMD152510
°C
2
Vicat softening temperature
--
ISO306/B50
°C
2
Vicat softening temperature
--
ISO306/B120
°C
2
Linear coefficient of thermal expansion
MD:-20to150°C
ASTME831
cm/cm/°C
2
Linear coefficient of thermal expansion
MD:23到150°C
ISO11359-2
cm/cm/°C
2
Linear coefficient of thermal expansion
TD:-40to150°C
ASTME831
cm/cm/°C
5
Linear coefficient of thermal expansion
TD:23to150°C
ISO11359-2
cm/cm/°C
5
Impact performance
Test Condition
Test Method
Unit
PEI/SABIC INNOVATIVE US/HU2200-1H1000
Impact strength of simply supported beam gap 7
23°C
ISO179/1eA
kJ/m²
6
Suspended wall beam gap impact strength 8
-30°C
ISO180/1A
kJ/m²
7
Suspended wall beam gap impact strength 8
23°C
ISO180/1A
kJ/m²
6
Dart impact equipped with measuring instruments
23°C,TotalEnergy
ASTMD3763
J
8