Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA66/6 TSG-30/4 BK9839 EMS-CHEMIE GERMANY
Grilon® 
Electrical/Electronic App、Wire and cable applicatio、Pipe fittings、Home appliance components、Connector、Application in the automo、Automotive Applications、Profile
Glass fiber reinforced、Thermal stability、Filler: Glass fiber reinf、30% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
PA66/6/EMS-CHEMIE GERMANY/TSG-30/4 BK9839
Shrinkage rate
TD
%
--
0
Shrinkage rate
MD
%
--
0
Water absorption rate
饱和,23°C
%
--
4
Water absorption rate
平衡,23°C,50%RH
%
--
1
Mechanical performance
Test Condition
Test Method
Unit
PA66/6/EMS-CHEMIE GERMANY/TSG-30/4 BK9839
Tensile stress
断裂
MPa
90.0
1
Thermal performance
Test Condition
Test Method
Unit
PA66/6/EMS-CHEMIE GERMANY/TSG-30/4 BK9839
Continuous use temperature
--3
°C
--
1
Continuous use temperature
--4
°C
--
2
Hot deformation temperature
1.8MPa,未退火
°C
--
2
Hot deformation temperature
8.0MPa,未退火
°C
--
1
Melting temperature 5
°C
--
2
Electrical performance
Test Condition
Test Method
Unit
PA66/6/EMS-CHEMIE GERMANY/TSG-30/4 BK9839
Surface resistivity
ohms
1E+10
-
Leakage Trace Index
V
600
-
Volume resistivity
ohms·cm
1E+12
1
hardness
Test Condition
Test Method
Unit
PA66/6/EMS-CHEMIE GERMANY/TSG-30/4 BK9839
Ball pressure hardness
MPa
130
2