Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

MABS 2802TR HD BASF GERMANY
Terlux®
Electrical field、Electrical appliances、Electronic field
Chemical resistance、transparent
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Physical properties
Test Condition
Test Method
Unit
MABS/BASF GERMANY/2802TR HD
Molding shrinkage rate
ASTM D955
%
0
Melt index (flow coefficient)
ASTM D1238/ISO 1133
g/10min
1
Water absorption rate 23 ℃/24h
ASTM D570/ISO 62
%
0
Mechanical performance
Test Condition
Test Method
Unit
MABS/BASF GERMANY/2802TR HD
Charpy notch impact strength
-30℃
KJ/m
2
I
Tensile modulus
ASTM D638/ISO 527
kg/cm²(MPa)[Lb/in²]
2
Tensile modulus
MPa
2000
I
tensile strength
ASTM D638/ISO 527
kg/cm²(MPa)[Lb/in²]
4
Yield stress
50mm/min
MPa
48
I
IZOD notch impact strength
ASTM D256/ISO 179
kg·cm/cm(J/M)ft·lb/in
1
IZOD notch impact strength
ASTM D256/ISO 179
kg·cm/cm(J/M)ft·lb/in
8
Thermal performance
Test Condition
Test Method
Unit
MABS/BASF GERMANY/2802TR HD
Hot deformation temperature
ASTM D648/ISO 75
℃(℉)
9
Hot deformation temperature
0.45MPa
℃
94
I
vicat softening point
ASTM D1525/ISO R306
℃(℉)
1
Vicat softening temperature
VST/A/50
℃
105
I
Vicat softening temperature
VST/B/50
℃
93
I
Electrical performance
Test Condition
Test Method
Unit
MABS/BASF GERMANY/2802TR HD
Surface resistivity
100V
Ohm
1E+15
I
Dielectric strength
kV/mm
34
I
Dielectric loss factor
100Hz
E-4
160
I
Dielectric loss factor
1MHz
E-4
140
I
Basic performance
Test Condition
Test Method
Unit
MABS/BASF GERMANY/2802TR HD
density
Kg/m
1080
I
Water absorption rate
equilibrium in water at 23°C
%
0.7
s