Need Help? Contact Us service@plas.com
Get App

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
POK M330F HYOSUNG KOREA
POKETONE™ 
Electronic appliances、Industrial materials、automobile
High mobility、High impact resistance、High chemical resistance、High wear resistance、High gas barrier、High flame retardancy
TDS
MSDS
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
POK/HYOSUNG KOREA/M330F
Saturation
ASTM D570,ISO 62
%
2
Melt mass flow rate
240℃,2.16kg  
ASTM D1238
g/10min
6
Shrinkage rate
MD, 3 mm  
ASTM D955
%
2
Shrinkage rate
TD, 3 mm  
ASTM D955
%
2
Shrinkage rate
MD, 2 mm  
ASTM D955
%
1
Shrinkage rate
TD, 2 mm  
ASTM D955
%
1
Water absorption rate
平衡,50%RH  
ASTM D570,ISO 62
%
0
Mechanical performance
Test Condition
Test Method
Unit
POK/HYOSUNG KOREA/M330F
Tensile elongation at break
ASTM D638,ISO 527-1
%
3
Tensile modulus
ASTM D638
Mpa
1
Tensile modulus
ISO 527-1
Mpa
1
Tensile strength
屈服  
ASTM D638,ISO 527-1
Mpa
6
Tensile yield elongation
ASTM D638,ISO 527-1
%
2
Bending strength
ASTM D790,ISO 178
Mpa
5
Thermal performance
Test Condition
Test Method
Unit
POK/HYOSUNG KOREA/M330F
Hot deformation temperature
66psi  
ASTM D648
°C
2
Hot deformation temperature
264psi  
ASTM D648
°C
1
Hot deformation temperature
0.45 MPa  
ISO 75
°C
1
Hot deformation temperature
1.8 MPa  
ISO 75
°C
9
Melting temperature
ASTM D955,ISO 11357
°C
2
Vicat softening point
5 kg  
ASTM D-1525
°C
1
Vicat softening point
50 N  
ISO 306/B50
°C
1
Electrical performance
Test Condition
Test Method
Unit
POK/HYOSUNG KOREA/M330F
Surface resistivity
ASTM D257
ohm/sq
1
Dielectric strength
短期,3 mm  
ASTM D149
KV/mm
1
Dielectric strength
短期,2 mm  
ASTM D149
KV/mm
1
Arc resistance
ASTM D495
sec
1
Volume resistivity
ASTM D257
ohms·cm
1
Compared to the leakage trace index
IEC 112
V
6
Impact performance
Test Condition
Test Method
Unit
POK/HYOSUNG KOREA/M330F
Falling hammer impact
23℃  
ISO 6603-2
J
5
Impact strength of cantilever beam gap
23℃  
ASTM D256
kJ/m²
9
Impact strength of cantilever beam gap
23℃  
ISO 180/1A
kJ/m²
7
Impact strength of cantilever beam gap
-10℃  
ASTM D256
kJ/m²
6
Impact strength of cantilever beam gap
-10℃  
ISO 180/1A
kJ/m²
4
Impact strength of cantilever beam gap
-30℃  
ASTM D256
kJ/m²
4
Impact strength of cantilever beam gap
-30℃  
ISO 180/1A
kJ/m²
3