Technical Data Sheet
Physical properties | Test Condition | Test Method | Test Result | Unit |
---|
density | | ASTM D792/ISO 1183 | 1.97 | |
Molding shrinkage rate | | ASTM D955 | 0.2 | % |
Water absorption rate 23 ℃/24h | | ASTM D570/ISO 62 | 0.02 | % |
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | Flow | 东丽法 | 0.15 | % |
Shrinkage rate | 垂重方向 | 东丽法 | 0.55 | % |
Water absorption rate | (23°C,24hr) | ISO62 | 0.02 | % |
Flowing Long | 320℃,98MPa,1mm厚 | 东丽法 | 90 | |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
abrasion | | ASTM D-1044 | 70 | mg/1000回 |
Limit PV value | | 东丽法 | 815 | KJ/m |
Curved elastic body | | ASTM D-790 | 17.6 | GPa |
hardness | | ASTM D-785 | 123 | 洛氏 |
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | 18 | kJ/m² |
Fracture strength | | ASTM D-732 | 60 | |
shear strength | | ISO178 | 60 | Mpa |
Tensile strength | | ASTM D-638 | 140 | Mpa |
friction coefficient | 对钢 | ASTM D-1894 | 0.30 | |
Charpy Notched Impact Strength | 23°C | ISO179/1eA | 8.0 | kJ/m² |
impact strength | Notched23℃ | ASTM D-256 | 90 | J/m |
impact strength | Unnotched23℃ | ASTM D-256 | 20 | KJ/m |
elongation at break | | ASTM D638/ISO 527 | 0.8 | % |
elongation at break | 23°C | ISO527-2 | 0.8 | % |
tensile strength | | ASTM D638/ISO 527 | 130 | kg/cm²(MPa)[Lb/in²] |
tensile strength | 23°C | ISO527-2 | 130 | Mpa |
tensile strength | | ASTM D-638 | 1.2 | % |
Rockwell hardness | | ASTM D785 | 123 | |
Bending modulus | | ASTM D790/ISO 178 | 22 | kg/cm²(MPa)[Lb/in²] |
Bending modulus | 23°C | ISO178 | 22000 | Mpa |
bending strength | 23°C | ISO178 | 210 | Mpa |
bending strength | | ASTM D790/ISO 178 | 210 | kg/cm²(MPa)[Lb/in²] |
bending strength | | ASTM D-790 | 200 | Mpa |
Charpy impact strength | | ASTM D256/ISO 179 | 8 | kg·cm/cm(J/M)ft·lb/in |
Charpy impact strength | | ASTM D256/ISO 179 | 18 | kg·cm/cm(J/M)ft·lb/in |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Combustibility | | UL-94 | V-0 | |
Vicat softening temperature | Melting Temperature | ISO11357-3 | 278 | °C |
Combustibility (rate) | | UL94 | V-0 | |
Hot deformation temperature | | ASTM D648/ISO 75 | >260 | ℃(℉) |
Hot deformation temperature | 1.80MPaAnnealed | ISO75-2/Af | >260 | °C |
Hot deformation temperature | 1.82MPa | ASTM D-648 | >260 | °C |
melting point | | | 278 | ℃(℉) |
Linear expansion coefficient | | ASTM D696/ISO 11359 | 1.7 | mm/mm.℃ |
Rongdian | | DSC | 278 | °C |
Coefficient of linear expansion | MD | ISO11359-2 | 1.7E-05 | cm/cm/°C |
Coefficient of linear expansion | TD | ISO11359-2 | 2.4E-05 | cm/cm/°C |
Line expansion coefficient | Flow | ASTM D-696 | 1.6 | |
Line expansion coefficient | 垂重方向 | ASTM D-696 | 2.4 | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Arc resistance W level | | ASTM D-495 | 182 | 秒 |
Insulation strength | | IEC60243-1 | 19 | KV/mm |
Volume resistance | | IEC60093 | 1E+19 | Ω.cm |
permittivity | 10 | ASTM D-150 | 5.8 | |
Induced positive connection | 10 | ASTM D-150 | 0.002 | |
Inherent resistance of volume | | ASTM D-257 | 10 | Ω.m |
Insulation breakdown voltage | | ASTM D-149 | 15 | MV/m |
Dissipation factor | 23°C | IEC60250 | 2E-03 | 1MHz |
Dielectric constant | | ASTM D150/IEC 60250 | 5 | |
Dielectric constant | 23°C | IEC60250 | 5.1 | 1MHz |
Volume resistivity | | ASTM D257/IEC 60093 | 1014 | Ω.cm |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell hardness | | ISO2039-2 | 123 | R |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
Fire rating | | UL-94 | 0.36mm | V-0 |
Fire rating | | UL-94 | 0.74mm | V-0 |
Fire rating | | UL-94 | 1.50mm | V-0 |
Fire rating | | UL-94 | 3.00mm | V-0 |
Fire rating | | UL-94 | 2.00mm | V-0,5VA |
Basic performance | Test Condition | Test Method | Test Result | Unit |
---|
Water absorption rate | | ASTM D-570 | 0.02 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.