Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density | | ASTM D792/ISO 1183 | 1.97 | |
Modeling Shrinkage | | ASTM D955 | 0.2 | % |
Moisture Absorption 23℃/24H | | ASTM D570/ISO 62 | 0.02 | % |
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | Flow | 东丽法 | 0.15 | % |
Modeling Shrinkage | 垂重方向 | 东丽法 | 0.55 | % |
Moisture Absorption | (23°C,24hr) | ISO62 | 0.02 | % |
Spiral Flow | 320℃,98MPa,1mm厚 | 东丽法 | 90 | |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Taber Abrasion Resistance | | ASTM D-1044 | 70 | mg/1000回 |
PV | | 东丽法 | 815 | KJ/m |
Flexural Strength | | ASTM D-790 | 17.6 | GPa |
hardness | | ASTM D-785 | 123 | 洛氏 |
Charpy Unnotched Impact Strength | 23°C | ISO179/1eU | 18 | kJ/m² |
Tensile Strength(Break) | | ASTM D-732 | 60 | |
Shearing Strength | | ISO178 | 60 | Mpa |
Tensile strength | | ASTM D-638 | 140 | Mpa |
Coefficient of Friction | 对钢 | ASTM D-1894 | 0.30 | |
Charpy Notched Impact Strength | 23°C | ISO179/1eA | 8.0 | kJ/m² |
Impact Strength | Notched23℃ | ASTM D-256 | 90 | J/m |
Impact Strength | Unnotched23℃ | ASTM D-256 | 20 | KJ/m |
Tensile Elongation?(Break) | | ASTM D638/ISO 527 | 0.8 | % |
Tensile Elongation?(Break) | 23°C | ISO527-2 | 0.8 | % |
Tensile Strength | | ASTM D638/ISO 527 | 130 | kg/cm²(MPa)[Lb/in²] |
Tensile Strength | 23°C | ISO527-2 | 130 | Mpa |
Tensile Strength | | ASTM D-638 | 1.2 | % |
Rockwell Hardness | | ASTM D785 | 123 | |
Flexural Modulus | | ASTM D790/ISO 178 | 22 | kg/cm²(MPa)[Lb/in²] |
Flexural Modulus | 23°C | ISO178 | 22000 | Mpa |
Flexural Strength | | ASTM D-790 | 200 | Mpa |
Flexural Strength | | ASTM D790/ISO 178 | 210 | kg/cm²(MPa)[Lb/in²] |
Flexural Strength | 23°C | ISO178 | 210 | Mpa |
Charpy impact strength | | ASTM D256/ISO 179 | 8 | kg·cm/cm(J/M)ft·lb/in |
Charpy impact strength | | ASTM D256/ISO 179 | 18 | kg·cm/cm(J/M)ft·lb/in |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Flammability | | UL-94 | V-0 | |
Vicat Softening Temperature | Melting Temperature | ISO11357-3 | 278 | °C |
Burning Rate | | UL94 | V-0 | |
Deflection Temperature Under Load? | | ASTM D648/ISO 75 | >260 | ℃(℉) |
Deflection Temperature Under Load? | 1.82MPa | ASTM D-648 | >260 | °C |
Deflection Temperature Under Load? | 1.80MPaAnnealed | ISO75-2/Af | >260 | °C |
Melting Temperature | | | 278 | ℃(℉) |
Linear expansion coefficient | | ASTM D696/ISO 11359 | 1.7 | mm/mm.℃ |
Melting Temperature | | DSC | 278 | °C |
Coefficient of Linear Thermal Expansion | MD | ISO11359-2 | 1.7E-05 | cm/cm/°C |
Coefficient of Linear Thermal Expansion | TD | ISO11359-2 | 2.4E-05 | cm/cm/°C |
Coefficient of Linear Thermal Expansion | Flow | ASTM D-696 | 1.6 | |
Coefficient of Linear Thermal Expansion | 垂重方向 | ASTM D-696 | 2.4 | |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Arc Resistance | | ASTM D-495 | 182 | 秒 |
Insulation strength | | IEC60243-1 | 19 | KV/mm |
Volume Resistivity | | IEC60093 | 1E+19 | Ω.cm |
Dissipation Factor | 10 | ASTM D-150 | 5.8 | |
Dielectric Constant | 10 | ASTM D-150 | 0.002 | |
Volume Resistivity | | ASTM D-257 | 10 | Ω.m |
Insulation Resistance | | ASTM D-149 | 15 | MV/m |
Dissipation Factor? | 23°C | IEC60250 | 2E-03 | 1MHz |
Dielectric Constant | | ASTM D150/IEC 60250 | 5 | |
Dielectric Constant | 23°C | IEC60250 | 5.1 | 1MHz |
Volume Resistivity | | ASTM D257/IEC 60093 | 1014 | Ω.cm |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | | ISO2039-2 | 123 | R |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Fire rating | | UL-94 | 0.36mm | V-0 |
Fire rating | | UL-94 | 0.74mm | V-0 |
Fire rating | | UL-94 | 1.50mm | V-0 |
Fire rating | | UL-94 | 3.00mm | V-0 |
Fire rating | | UL-94 | 2.00mm | V-0,5VA |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | | ASTM D-570 | 0.02 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.