Technical Data Sheet
Physical properties | Test Condition | Test Method | Test Result | Unit |
---|
density | | ASTM D792/ISO 1183 | 1.66 | |
Molding shrinkage rate | | ASTM D955 | 0.2 | % |
Water absorption rate 23 ℃/24h | | ASTM D570/ISO 62 | 0.02 | % |
physical property | Test Condition | Test Method | Test Result | Unit |
---|
Shrinkage rate | TD:3.00mm2 | 内部方法 | 0.80 | % |
Shrinkage rate | MD:3.00mm4 | 内部方法 | 0.20 | % |
Water absorption rate | 23°C,24hr | ISO62 | 0.020 | % |
Mechanical performance | Test Condition | Test Method | Test Result | Unit |
---|
Tensile stress | Yield,23°C | ISO527-2 | 205 | Mpa |
Tensile strain | Break,23°C | ISO527-2 | 2.0 | % |
Bending stress | 23°C | ISO178 | 300 | Mpa |
Taber abraser | 1000Cycles | ISO9352 | 50.0 | mg |
shear strength | 23°C | JISK7214 | 80.0 | Mpa |
Friction coefficient 4 | | | 0.24 | |
elongation at break | | ASTM D638/ISO 527 | 2 | % |
tensile strength | | ASTM D638/ISO 527 | 205 | kg/cm²(MPa)[Lb/in²] |
Rockwell hardness | | ASTM D785 | 122 | |
Bending modulus | | ASTM D790/ISO 178 | 14.5 | kg/cm²(MPa)[Lb/in²] |
Bending modulus | 23°C | ISO178 | 14500 | Mpa |
bending strength | | ASTM D790/ISO 178 | 300 | kg/cm²(MPa)[Lb/in²] |
Charpy impact strength | | ASTM D256/ISO 179 | 12 | kg·cm/cm(J/M)ft·lb/in |
Charpy impact strength | | ASTM D256/ISO 179 | 60 | kg·cm/cm(J/M)ft·lb/in |
Thermal performance | Test Condition | Test Method | Test Result | Unit |
---|
Combustibility (rate) | | UL94 | V-0 | |
Hot deformation temperature | | ASTM D648/ISO 75 | >260 | ℃(℉) |
Hot deformation temperature | 1.8MPa,Unannealed | ISO75-2/A | 260 | °C |
melting point | | | 278 | ℃(℉) |
Linear expansion coefficient | | ASTM D696/ISO 11359 | 2.3 | mm/mm.℃ |
Linear coefficient of thermal expansion | MD | ISO11359-2 | 2.3E-05 | cm/cm/°C |
Linear coefficient of thermal expansion | TD | ISO11359-2 | 3.5E-05 | cm/cm/°C |
Melting temperature | | ISO11357-3 | 278 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Dielectric strength | | IEC60243-1 | 24 | KV/mm |
Dielectric constant 6 | 23°C,1MHz | IEC60250 | 3.60 | |
Dissipation factor 5 | 23°C,1MHz | IEC60250 | 2E-03 | |
Dielectric constant | | ASTM D150/IEC 60250 | 3.6 | |
Volume resistivity | | ASTM D257/IEC 60093 | 1014 | Ω.cm |
Volume resistivity | | IEC60093 | 1E+16 | ohms·cm |
Impact performance | Test Condition | Test Method | Test Result | Unit |
---|
Impact strength of simply supported beam without notch | 23°C | ISO179 | 60 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell hardness | R-Scale | ISO2039-2 | 122 | |
flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.200mm | UL94 | V-0 | |
Supplementary Information | Test Condition | Test Method | Test Result | Unit |
---|
BarFlowLength6 | 320°C,1.00mm | 内部方法 | 120 | mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.