Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | MD | 内部方法 | 0.17 | % |
Modeling Shrinkage | TD | 内部方法 | 0.40 | % |
Moisture Absorption | Saturation | ASTMD570 | 0.020 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Elongation | Break | ASTMD638 | 4.5 | % |
Flexural Modulus | 23°C | ASTMD790 | 12500 | Mpa |
Flexural Strength | Yield,23°C | ASTMD790 | 140 | Mpa |
Shearing Strength | | ASTMD732 | 54.0 | Mpa |
Tensile Strength | Yield | ASTMD638 | 130 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | 1.8MPa,Unannealed | ASTMD648 | 270 | °C |
Linear thermal expansion coefficient | MD:150°C | 内部方法 | 4E-06 | cm/cm/°C |
Linear thermal expansion coefficient | TD:150°C | 内部方法 | 8.1E-05 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Comparative Tracking Index | | IEC60112 | 190 | V |
Dissipation Factor? | 1MHz | ASTMD150 | 0.038 | |
Dissipation Factor? | 1.00GHz | ASTMD150 | 4E-03 | |
Dielectric Constant | 1MHz | ASTMD150 | 3.80 | |
Dielectric Constant | 1.00GHz | ASTMD150 | 3.60 | |
Arc Resistance | | ASTMD495 | 140 | sec |
Volume Resistivity | | ASTMD257 | 1E+15 | ohms·cm |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Unnotched Izod Impact Strength | 6.40mm | ASTMD256 | 270 | J/m |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | R-Scale | ASTMD785 | 97 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
UL flame retardant rating | 0.30mm,NC,BK | UL94 | V-0 | |
Oxygen Index | | ISO 489 | 44 | % |
Supplementary information | Test Condition | Test Method | Test Result | Unit |
---|
SolderingResistance | | 内部方法 | 280 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.