Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Melt index | | ASTM D1238 | 22 | g/10min |
Moisture Absorption | | ASTM D570 | 0.2 | % |
Moulding shrinkage | | ASTM D955 | 0.5-0.7 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Notched Impact Strength | | ASTM D256 | 80 | kg.cm/cm |
Tensile Strength | | ASTM D638 | 630 | kg/cm |
Tensile Elongation | | ASTM D638 | 60 | % |
Rockwell Hardness | | ASTM D785 | 77 | M |
Flexural Modulus | | ASTM D790 | 24000 | kg/cm |
Flexural Strength | | ASTM D790 | 920 | kg/cm |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Deflection Temperature Under Load? | -,0.45Mpa | ASTM D648 | 136 | °C |
Deflection Temperature Under Load? | -,1.8Mpa | ASTM D648 | 125 | °C |
Coefficient of Linear Thermal Expansion | | ASTM D696 | 6-8 | |
Vicat Softening Temperature | | ASTM D1525 | 153 | °C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Loss factor | | ASTM D150 | 2.95 | |
Volume Resistivity | 10 | ASTM D257 | 3 | Ω.cm |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
Transmittance | | ASTM D1003 | 89 | % |
Refractive index of light | | ASTM D542 | 1.585 | |
Haze | | ASTM D1003 | <0.8 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.