Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | | ISO294-4 | 0.40to0.70 | % |
Moisture Absorption | Saturation,23°C | ISO62 | 0.70 | % |
Apparent Density | | | 0.59 | g/cm³ |
Melt Volume flow Rate | 220°C/10.0kg | ISO1133 | 2.00 | cm3/10min |
Melt Volume flow Rate | 220°C/21.6kg | ISO1133 | 17.0 | cm3/10min |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Stress | Yield,23°C | ISO527-2 | 48.0 | Mpa |
Tensile Strain | Yield,23°C | ISO527-2 | 4.0 | % |
Flexural Stress | | ISO178 | 70.0 | Mpa |
Nominal Tensile Strain at Break | 23°C | ISO527-2 | 12 | % |
Tensile Creep Modulus | 1000hr | ISO899-1 | 1250 | Mpa |
Tensile Modulus | | ISO527-2 | 2000 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Vicat Softening Temperature | -- | ISO306/B50 | 93.0 | °C |
Vicat Softening Temperature | -- | ISO306/A50 | 105 | °C |
Thermal Conductivity | | DIN52612 | 0.17 | W/m/K |
Heat Deflection Temperature | 0.45MPa,Annealed | ISO75-2/B | 94.0 | °C |
Heat Deflection Temperature | 1.8MPa,Annealed | ISO75-2/A | 90.0 | °C |
Linear thermal expansion coefficient | MD | ISO11359-2 | 8.0E-5to1.1E-4 | cm/cm/°C |
Electrical performance | Test Condition | Test Method | Test Result | Unit |
---|
Surface Resistivity | | IEC60093 | 1E+15 | ohms |
Dielectric Constant | 100Hz | IEC60250 | 2.90 | |
Volume Resistivity | | IEC60093 | 1E+15 | ohms·cm |
Dissipation Factor? | 100Hz | IEC60250 | 0.016 | |
Dissipation Factor? | 1MHz | IEC60250 | 0.014 | |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Unnotched Impact Strength | -30°C | ISO179 | 80 | kJ/m² |
Charpy Unnotched Impact Strength | 23°C | ISO179 | 120 | kJ/m² |
hardness | Test Condition | Test Method | Test Result | Unit |
---|
Ball Indentation Hardness | | ISO2039-1 | 70.0 | Mpa |
optical performance | Test Condition | Test Method | Test Result | Unit |
---|
Refractive index of light | | ISO489 | 1.540 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.